4 inputs for thermocouple sensorsSensor types J, K, N, R and SAdditional direct raw value measurement for other sensor typesTerminal temperature compensation

The module is a temperature module for type J, K, N, R and S thermocouple sensors. The selected sensor type is used for all 4 inputs.

Specification

I/O module

4 inputs for thermocouple sensors

B&R ID code

0x1486

Status indicators

I/O function per channel, supply voltage, bus function

Inputs

4x M12, A-coded

I/O power supply

M8, 4-pin

Internal I/O

2.6 W

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA IIA T5 Gc
IP67, Ta = 0 – Max. 60°C
TÜV 05 ATEX 7201X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

KC

Yes

Nominal voltage

24 VDC

Voltage range

18 to 30 VDC

Integrated protective function

Reverse polarity protection

Input

Thermocouple

Digital converter resolution

16-bit

Filter time

Configurable between 2 and 20 ms

Output format

INT

Type J: Fe-CuNi

0.0024%/°C

Type K: NiCr-Ni

0.0030%/°C

Type N: NiCrSi-NiSi

0.0035%/°C

Type S: PtRh10-Pt

0.0089%/°C

Type R: PtRh13-Pt

0.0079%/°C

Terminal temperature

1 LSB = 0.1°C

Raw value

±65.534 mV

Terminal temperature compensation

Using thermocouple connector X67AC9A02 (accessory)

Sensor standard

IEC 60584-1

Sensor temperature

1 LSB = 0.1°C

Raw value output with respect to gain

1 LSB = 1 µV or 2 µV

Range undershoot

0x8001

Range overshoot

0x7FFF

Open circuit

0x7FFF

Open inputs

0x7FFF

General fault

0x8000

Conversion procedure

Sigma-delta

Linearization method

Software

Permissible input signal

Short-term ±30 VDC

Gain

±0.040%

Max. gain drift

0.0123%/°C

Nonlinearity

<0.002%

DC

>70 dB

50 Hz

>70 dB

Common-mode range

±12 VDC

Crosstalk between channels

<-70 dB

Terminal temperature error

Typ. ±2°C after 10 min.

Insulation voltage between channel and bus

500 Veff

Conversion time

62 ms per channel with 50 Hz filter + 62 ms per cycle for terminal temperature measurement with 50 Hz filter

Cutoff frequency

4 Hz / First-order filter

Slope

-20 dB

Electrical isolation

Channel isolated from bus

Channel not isolated from channel

Any

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP67

Operation

-25 to 60°C

Derating

Storage

-40 to 85°C

Transport

-40 to 85°C

Width

53 mm

Height

85 mm

Depth

42 mm

Weight

205 g

M8

Max. 0.4 Nm

M12

Max. 0.6 Nm