Fast delivery within 72 Hours

B&R X20cDS438A

4 IO-Link devices4 digital channels, can be configured as input or output24 VDC and GND for sensor/actuator supply

The module is an IO-Link master that all…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

4 IO-Link devices4 digital channels, can be configured as input or output24 VDC and GND for sensor/actuator supply

The module is an IO-Link master that allows intelligent sensors and actuators to be connected to the X20 system in accordance with the IO-Link standard. The module can be used to operate up to 4 IO-Link devices. All IO-Link channels can be used either as standard digital inputs or outputs.

Specification

I/O moduleIO-Link master with 4 IO-Link interfaces
B&R ID code0xEB57
Status indicatorsIO-Link, operating state, module status
Module run/errorYes, using LED status indicator and software
C/Q statusYes, using LED status indicator and software
Cable type3-pin standard sensor cable, unshielded
Cable lengthMax. 20 m
Line capacitanceMax. 3 nF
Loop resistanceMax. 6 Ω
Bus0.01 W
Internal I/O0.71 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 0.3 V
Power consumptionMax. 12 W per IO-Link interface
Short-circuit proofYes
Switch-off delayConfigurable using software
Switch-off durationConfigurable using software
COM14.8 kbaud
COM238.4 kbaud
COM3230.4 kbaud
Max. connection capacity22 nF (cable + IO-Link device)
Max. load96 Ω / 250 mA
Data format1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit
Bus level24 VDC (active), 0 VDC (resting voltage)
VariantBipolar, positive and negative switching
Peak short-circuit current<1.3 A
Residual voltage<0.7 VDC at nominal current 0.25 A
Switching voltageI/O power supply minus voltage drop for short-circuit protection and semiconductor switch
Voltage drop on semiconductor switchMax. 0.5 VDC at 0.25 A
Switching frequencyTyp. 25 kHz 300 kHz in IO-Link master mode
0 → 1<10 µs
1 → 0<10 µs
Switch-on in the event of overload shutdown or short-circuit shutdownConfigurable with software
Nominal voltage24 VDC
Nominal output current0.25 A
Total nominal currentMax. 1 A
Output circuitSink or source
Switching frequency (resistive load)Max. 500 Hz
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
Input characteristics per EN 61131-2Type 1
Hardware300 ns
Software
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCTyp. 4 mA
Input resistanceTyp. 6 kΩ
Low<5 VDC
High>15 VDC
Electrical isolationBus isolated from IO-Link IO-Link not isolated from IO-Link
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
OperationUp to 100%, condensing
NoteOrder 1x terminal block X20TB12 separately, order 1x bus module X20cBM11 separately.
Pitch12.5+0.2 mm