Fast delivery within 72 Hours
B&R X20cDS438A
4 IO-Link devices4 digital channels, can be configured as input or output24 VDC and GND for sensor/actuator supply
The module is an IO-Link master that all…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
4 IO-Link devices4 digital channels, can be configured as input or output24 VDC and GND for sensor/actuator supply
The module is an IO-Link master that allows intelligent sensors and actuators to be connected to the X20 system in accordance with the IO-Link standard. The module can be used to operate up to 4 IO-Link devices. All IO-Link channels can be used either as standard digital inputs or outputs.
Specification
| I/O module | IO-Link master with 4 IO-Link interfaces |
|---|---|
| B&R ID code | 0xEB57 |
| Status indicators | IO-Link, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| IO-Link operating state | Yes, using LED status indicator and software |
| C/Q status | Yes, using LED status indicator and software |
| Cable type | 3-pin standard sensor cable, unshielded |
| Cable length | Max. 20 m |
| Line capacitance | Max. 3 nF |
| Loop resistance | Max. 6 Ω |
| Bus | 0.01 W |
| Internal I/O | 0.71 W |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| Voltage | I/O power supply minus voltage drop for short-circuit protection |
| Voltage drop for short-circuit protection at 0.5 A | Max. 0.3 V |
| Power consumption | Max. 12 W per IO-Link interface |
| Short-circuit proof | Yes |
| Switch-off delay | Configurable using software |
| Switch-off duration | Configurable using software |
| COM1 | 4.8 kbaud |
| COM2 | 38.4 kbaud |
| COM3 | 230.4 kbaud |
| Max. connection capacity | 22 nF (cable + IO-Link device) |
| Max. load | 96 Ω / 250 mA |
| Data format | 1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit |
| Bus level | 24 VDC (active), 0 VDC (resting voltage) |
| Variant | Bipolar, positive and negative switching |
| Peak short-circuit current | <1.3 A |
| Residual voltage | <0.7 VDC at nominal current 0.25 A |
| Switching voltage | I/O power supply minus voltage drop for short-circuit protection and semiconductor switch |
| Voltage drop on semiconductor switch | Max. 0.5 VDC at 0.25 A |
| Switching frequency | Typ. 25 kHz 300 kHz in IO-Link master mode |
| 0 → 1 | <10 µs |
| 1 → 0 | <10 µs |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Configurable with software |
| Insulation voltage between IO-Link and bus | 500 Veff |
| Nominal voltage | 24 VDC |
| Nominal output current | 0.25 A |
| Total nominal current | Max. 1 A |
| Output circuit | Sink or source |
| Switching frequency (resistive load) | Max. 500 Hz |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads |
| Input characteristics per EN 61131-2 | Type 1 |
| Hardware | 300 ns |
| Software | – |
| Input circuit | Sink |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Typ. 4 mA |
| Input resistance | Typ. 6 kΩ |
| Low | <5 VDC |
| High | >15 VDC |
| Electrical isolation | Bus isolated from IO-Link IO-Link not isolated from IO-Link |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | – |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | Up to 100%, condensing |
| Note | Order 1x terminal block X20TB12 separately, order 1x bus module X20cBM11 separately. |
| Pitch | 12.5+0.2 mm |

Reviews