B&R 8I86T400400.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 4.0 kW, EMC filter and brake chopper.Order number – ACOPOSinverter P86:8I86T400400.0P-100: Inverter with POWERLINK communication card

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 4.0 kW, EMC filter and brake chopper.Order number – ACOPOSinverter P86:8I86T400400.0P-100: Inverter with POWERLINK communication card

Specification

CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ULcULus E225616Power conversion equipment
Specified on nameplate4 kW (5 HP)
Mains input voltage3x 380 VAC -15% to 480 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 480 VAC)8.8 kVA
Max. assumed short-circuit current (Isc)(short-circuit current at connection point)5 kA
Inrush currentMax. 36.1 A
At 380 VAC13.4 A
At 480 VAC10.6 A
External cooling136 W
Integrated EMC filterYes
Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)C2 level at 4 kHz with 50 m cable
Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)C3 level at 4 kHz with 100 m cable
With add-on filter8I0FT025.200-1
Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)
Nominal output current9.3 A
At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power)No derating (up to 50°C)
Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Starting at 1000 m above sea level1%, per 100 m
Max. transient current for 60 s14 A
Max. transient current for 2 s16.7 A
Output frequency range0.1 to 599 Hz
Nominal clock frequency4 kHz
Min.2 kHz
Max.16 kHz
Shielded cable100 m
Non-shielded cable100 m
Induction motorSensorless vector control:1. Voltage controlled with constant torque→ Default mode2. Voltage controlled with variable torque→ Energy-saving mode, e.g. for fans and pumpsVector control with encoder:1. Current-controlled with constant torque→ Default modeSensorless slip control:1. With V/f characteristic curve for constant torque→ Default mode2. With V/f characteristic curve for constant torque (up to 6 f ranges)→ Mode for individual special applications3. With V/f characteristic curve for quadratically increasing torque→ Energy-saving mode, e.g. for fans and pumps
Synchronous motorSensorless vector control:1. Voltage controlled with constant torque→ Default modeVector control with encoder:1. Current-controlled with constant torque→ Default mode
Main protective functions of inverterThermal protection against power stage overheatingProtection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply
Integrated dynamic brake transistorsYes
Min. resistance value (external)31 Ω
Input voltage24 VDC (min. 20.4 VDC, max. 27 VDC)
Current500 Ω
Output voltage 24 VDC24 VDC (min. 20.4 VDC, max. 27 VDC)
Max. output current at 24 VDCMax. 200 mA
Output voltage 10 VDC10.5 VDC ±5%
Max. output current at 10 VDCMax. 10 mA
TypeType 3
Quantity1
Nominal voltage30 VDC / 250 VAC
Input circuitSource
Low<0.6 V
High>2.5 V
Input - ACOPOSinverterYes
Input - InputNo
Sampling time5 ms ±1 ms
Input impedance2.2 kΩ
Input frequency0 to 30 kHz
Nonlinearity±0.2%
Basic accuracy±1% with temperature fluctuation of 60°C
Voltage470 Ω
Resolution10-bit
Max. voltage30 VDC
Output circuitSource or sink
Max. current100 mA
Switching current rangeMin. switching current: 5 mA at 24 VDCMax. switching current:R1: At cos φ = 1: Max. 3 A / At cos φ = 0.4: Max. 2 AR2: At cos φ = 1: Max. 5 A / At cos φ = 0.4: Max. 2 A
Relay 11 changeover contact
Relay 21 normally open contact
Output - ACOPOSinverterYes
Output - OutputNo
Response time (max.)5 ms ±0.5 ms
Output0 to 10 VDC or 0 to 20 mA
Power dissipation relative to continuous apparent powerIE2 (10, 25): 1% (3x 380 VAC), 0.7% (3x 480 VAC)IE2 (50, 25): 0.9% (3x 380 VAC), 0.7% (3x 480 VAC)IE2 (10, 50): 1.2% (3x 380 VAC), 0.9% (3x 480 VAC)IE2 (50, 50): 1.1% (3x 380 VAC), 0.9% (3x 480 VAC)IE2 (90, 50): 1.2% (3x 380 VAC), 1% (3x 480 VAC)IE2 (10, 100): 1.8% (3x 380 VAC), 1.3% (3x 480 VAC)IE2 (50, 100): 1.7% (3x 380 VAC), 1.4% (3x 480 VAC)IE2 (90, 100): 2% (3x 380 VAC), 1.7% (3x 480 VAC)
Nominal losses in standby mode15 W (3x 380 VAC), 16 W (3x 480 VAC)
Degree of protection per EN 61800-5-1IP20
Degree of protection per EN 60529IP20
Max. relative humidity per EN/IEC 60721-3-3 class 3K35 to 95%, non-condensing
Maximum installation elevation≤1000 m without derating1000 to 3000 m with Derating
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S3
Operating positionVertical mounting orientation ±10°
Operation-15 to 50°C without derating50 to 60°C with derating
Storage-40 to 70°C
Max. vibration resistance1 gn 9 to 200 Hz EN/IEC 60721-3-3 class 3M31.5 mm peak to peak 2 to 19 Hz EN/IEC 60721-3-3 class 3M3
Max. shock resistance15 gn (duration = 11 ms) per EN/IEC 60721-3-3 class 3M3
Width85 mm
Height270 mm
Depth232.5 mm
Weight2.3 kg