Fast delivery within 72 Hours
Wago 774-9993/106-302
Cable assembly WINSTA® RD A codingThe WINSTA® RD cable assembly 3-pole provides the foundation for assembly of fine-stranded and solid conductors. WAGO pluggable installation connectors are used when…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Cable assembly WINSTA® RD A codingThe WINSTA® RD cable assembly 3-pole provides the foundation for assembly of fine-stranded and solid conductors. WAGO pluggable installation connectors are used when requirements repeat or are planned on a defined pattern, for example for installing grid lighting or flush-mount lighting. The mechanical coding and color coding of the pluggable installation connector ensure error-free installation of the individual components – including protection against mismating. The pluggable installation connector is protected against ingress by solid objects in accordance with protection type IP20 (When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). The WINSTA® RD features a round design that is perfect for installation in conduits with an inner diameter of 20 mm, for example in construction of prefabricated houses. This product meets all the relevant fire protection requirements of fire class E; as a result it can be used in areas where fire safety is relevant.Fast, secure pluggable connections – cable assemblies from WAGOA socket and a free end are available. The WINSTA® Pluggable Connection System allows pluggable electrical installation. This saves time, lowers costs, and reduces the need for servicing. Take advantage of the pluggable version of our maintenance-free spring pressure connection technology too! Plan your installation with with fire class E from WAGO. effective protection against mismatingsaves time, since no wiring is required at the construction sitesuitable for any applicationcustom-engineered solutionsquick replacement of defective units during ongoing operation
Specification
Notes
| Note | Cables with a different fire class can be found in the eShop. |
|---|
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60664-1 |
|---|---|
| Nominal voltage (III/3) | 250 V |
| Rated impulse withstand voltage (III / 3) | 4 kV |
| Rated current | 16 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 250 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 16 A |
Electrical data - General information
| Note on contact resistance | approx. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket |
|---|
Connection data
| Total number of potentials | 3 |
|---|---|
| PE function | Preceding PE contact |
| Conductor preparation | ultrasonically tip-bonded |
Connection data - Connection 1
| Strip length | 9 mm / 0.35 inches |
|---|---|
| Pole number | 3 |
| Wire cross-section | 1.5 mm² |
| Strip length (outer insulation) | 55 mm |
| Connection type | Socket - Free end |
Physical data
| Width | 17.5 mm / 0.689 inches |
|---|---|
| Height | 17.5 mm / 0.689 inches |
| Total length | 3 m |
Mechanical data
| Use | General mains applications |
|---|---|
| Variable coding | No |
| Marking | L ⏚ N |
| Mating force of a plug-in connection | approx. 30 … 70 N (depending on pole number) |
| Retention force of a plug-in connection | when locked: > 80N |
| Unmating force of a plug-in connection | Unlocked: approx. 30 … 70 N (depending on pole number) |
| Number of mating cycles | 200, without resistive load |
| Connection type | Socket - free end |
| Type of pre-assembled cable | Connecting cable |
| Cable type | H05VV-F 3G1.5 |
| Protection type | IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!) |
Plug-in connection
| Mismating protection | Yes |
|---|---|
| Note on mismating protection | All WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while incorrectly rotated c.) plugging while laterally staggered |
| Locking lever | yes |
| Locking of plug-in connection | locking lever |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | white |
| Insulation material (main housing) | Polyamide (PA66) |
| Fire class per EN 50575 | Eca |
| Contact material | Copper or copper alloy; surface-treated |
| Contact plating | Tin |
| Fire load | 89.444 MJ |
| Connector color | white |
| Strain relief color | white |
| Sheathed cable color | white |
| Printing color of sheathed cable | black |
| Halogen-free | No |
| Silicon-free | Yes |
| Sheath material | PVC |
| Rubber cable | No |
| Weight | 303.8 g |
| Copper weight of the raw cable | 0.043 kg/m |
Environmental requirements
| Processing temperature | -5 … +40 °C |
|---|---|
| Continuous operating temperature | -35 … +85 °C |
| Note on continuous operating temperature | Cable for temperatures ≤ 70 °C (including halogen-free)Insulating parts for temperatures ≤ 105 °C |
Commercial data
| PU (SPU) | 1 pcs |
|---|---|
| Packaging type | unpacked |
| Country of origin | DE |
| GTIN | 4045454321185 |
| Customs tariff number | 85444290900 |
Product Classification
| UNSPSC | 26121629 |
|---|---|
| eCl@ss 10.0 | 27-44-06-04 |
| eCl@ss 9.0 | 27-44-06-04 |
| ETIM 9.0 | EC002587 |
| ETIM 10.0 | EC002587 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews