Fast delivery within 72 Hours

Wago 771-9973/006-405

Cable assembly WINSTA® MIDI rated current 16 AThe WINSTA® MIDI cable assembly 3-pole allows installation of fine-stranded and solid conductors. Our pluggable installation connectors with spring pressu…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Cable assembly WINSTA® MIDI rated current 16 AThe WINSTA® MIDI cable assembly 3-pole allows installation of fine-stranded and solid conductors. Our pluggable installation connectors with spring pressure connection technology work without screw connections. They allow fast, efficient, error-free installation in a large number of possible uses. For greater protection in electrical installations, the pluggable installation connector is provided with mechanical protection against mismating. The pluggable installation connector offers touch-proof protection with live components in accordance with protection type IP20 (When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). WINSTA® MIDI pluggable installation connectors with S coding in brown are primarily used in AC applications. The WINSTA® MIDI Pluggable Connection System with Push-in CAGE CLAMP® spring pressure connection technology facilitates safe electrification. Due to the built-in test slot, it is possible to check connections even when they are plugged in. That saves time and reduces installation labor and expense. According to the European CPR, the fire class of the cables used in construction is decisive for building safety, too. For buildings with medium-level safety requirements, cable assemblies with fire class E are suitable.Fast, error-free assembly thanks to cable assemblies from WAGOThe cable assembly is equipped with a socket and a plug. WINSTA® is the pluggable connection system that is ideally tailored to the strict requirements of electrical installation. It ensures error-free installation of cables and components, quickly and reliably. Now you can also cut installation expenses without compromising quality and safety: with protection against mismating eliminates the need for servicing and prevents unnecessary downtime. effective protection against mismatingfor automation controllerswith S coding for AC applications of distributed componentsexact dimensionsconvenient installation and commissioning

Specification

Notes

NoteCables with a different fire class can be found in the eShop.

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60664-1
Nominal voltage (III/3)250 V
Rated impulse withstand voltage (III / 3)4 kV
Rated current16 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage250 V
Rated impulse withstand voltage4 kV
Rated current16 A

Electrical data - General information

Note on contact resistanceapprox. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket

Connection data

Total number of potentials3

Connection data - Connection 1

Pole number3
Wire cross-section1.5 mm²
Connection typeSocket - Plug

Physical data

Pin spacing10 mm / 0.394 inches
Width27 mm / 1.063 inches
Height12.9 mm / 0.508 inches
Total length4 m

Mechanical data

UseSwitching function
CodingS
Variable codingNo
Marking1 2 L
Potential marking1 2 L
Mating force of a plug-in connectionapprox. 20 … 70 N (depending on pole number)
Retention force of a plug-in connectionwhen locked: > 80N
Unmating force of a plug-in connectionwhen unlocked: approx. 20 … 70 N (depending on pole number)
Number of mating cycles200, without resistive load
Connection typeSocket - Plug
Type of pre-assembled cableInterconnecting cable
Cable typeH05VV-F 3x1.5
Protection typeIP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)

Plug-in connection

Mismating protectionYes
Note on mismating protectionAll WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while rotated 180 c.) plugging while laterally staggeredd.) plugging one pole
Locking leverCan be retrofitted
Locking of plug-in connectionlocking lever
Note on locking systemAll connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug/socket).

Material data

Note (material data)Information on material specifications can be found here
Colorbrown
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire class per EN 50575Eca
Contact materialCopper or copper alloy; surface-treated
Contact platingTin
Fire load119.136 MJ
Connector colorbrown
Strain relief colorblack
Printing color of strain reliefwhite
Sheathed cable colorblack
Printing color of sheathed cablewhite
Halogen-freeNo
Silicon-freeYes
Sheath materialPVC
Rubber cableNo
Weight412.9 g
Copper weight of the raw cable0.043 kg/m

Environmental requirements

Processing temperature-5 … +40 °C
Continuous operating temperature-35 … +85 °C
Note on continuous operating temperatureCable for temperatures ≤ 70 °C (including halogen-free)Insulating parts for temperatures ≤ 105 °C

Commercial data

PU (SPU)1 pcs
Packaging typeunpacked
Country of originDE
GTIN4050821311256
Customs tariff number85444290900

Product Classification

UNSPSC26121629
eCl@ss 10.027-44-06-04
eCl@ss 9.027-44-06-04
ETIM 9.0EC002587
ETIM 10.0EC002587
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption