Fast delivery within 72 Hours
Wago 771-9285/017-201
Cable assembly WINSTA® MIDI I codingThe WINSTA® MIDI cable assembly with protection against mismating allows installation of solid and fine-stranded conductors. Our pluggable installation connectors w…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Cable assembly WINSTA® MIDI I codingThe WINSTA® MIDI cable assembly with protection against mismating allows installation of solid and fine-stranded conductors. Our pluggable installation connectors with spring pressure connection technology function entirely without screw connections. They allow fast, efficient, error-free installation in a large number of possible uses. The coding options reduce installation errors, allowing fast, maintenance-free wiring of all components. The pluggable installation connector is protected in accordance with protection type IP20 (When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). This means that users’ fingers will never come into contact with electrified contact elements. Regulated lighting equipment, as used in the DALI standard, for instance, is the primary domain of use of WINSTA® MIDI pluggable installation connectors with I coding. Important parameters in the selection of a pluggable installation connector are the rated current and voltage: They provide information about possible domains of use and applications. This product has a current rating of 20 A – as a result it is suitable for powerful loads. Our WINSTA® MIDI product line offers maximum flexibility for the electrical installation. Through its Push-in CAGE CLAMP® spring pressure connection technology, it ensures time-saving, error-free installation and offers flexibility for meeting an enormous variety of installation requirements. If you need to satisfy stricter safety standards, you should use cables with fire class B2. These are suitable for use in buildings with extremely high demands on safety. In the production of this cable assembly, halogens were deliberately omitted. This is an important contribution to climate protection.Fast, secure pluggable connections – cable assemblies from WAGOA socket and a plug are provided. The WINSTA® Pluggable Connection System allows pluggable electrical installation. This significantly reduces the need for servicing and lowers costs. Enjoy the benefits of the pluggable version of our maintenance-free spring pressure connection technology too! Plan your installation with with fire class B2 from WAGO. effective protection against mismatingsimple circuitswith I coding for use in building automation (lighting control)ready to install and use immediatelyconvenient installation and commissioning
Specification
Notes
| Note | Cables with a different fire class can be found in the eShop. |
|---|
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60664-1 |
|---|---|
| Nominal voltage (III/3) | 400 V |
| Rated impulse withstand voltage (III / 3) | 6 kV |
| Rated current | 20 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 400 V |
| Rated impulse withstand voltage | 6 kV |
| Rated current | 20 A |
Electrical data - General information
| Note on contact resistance | approx. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket |
|---|
Connection data
| Total number of potentials | 5 |
|---|---|
| PE function | Preceding PE contact |
Connection data - Connection 1
| Pole number | 5 |
|---|---|
| Wire cross-section | 2.5 mm² |
| Connection type | Socket - Plug |
Physical data
| Pin spacing | 10 mm / 0.394 inches |
|---|---|
| Width | 47 mm / 1.85 inches |
| Height | 15.38 mm / 0.606 inches |
| Total length | 2 m |
Mechanical data
| Use | DALI, Lighting Management |
|---|---|
| Coding | I |
| Variable coding | No |
| Marking | N ⏚ L DA- DA+ |
| Potential marking | N ⏚ L DA- DA+ |
| Mating force of a plug-in connection | approx. 20 … 70 N (depending on pole number) |
| Retention force of a plug-in connection | when locked: > 80N |
| Unmating force of a plug-in connection | when unlocked: approx. 20 … 70 N (depending on pole number) |
| Number of mating cycles | 200, without resistive load |
| Connection type | Socket - Plug |
| Type of pre-assembled cable | Interconnecting cable |
| Cable type | H05Z1Z1-F 5G2.5 |
| Protection type | IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!) |
Plug-in connection
| Mismating protection | Yes |
|---|---|
| Note on mismating protection | All WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while rotated 180 c.) plugging while laterally staggeredd.) plugging one pole |
| Locking lever | Can be retrofitted |
| Locking of plug-in connection | locking lever |
| Note on locking system | All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug/socket). |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | blue |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire class per EN 50575 | B2ca |
| Contact material | Copper or copper alloy; surface-treated |
| Contact plating | Tin |
| Fire load | 1.081 MJ |
| Connector color | blue |
| Strain relief color | black |
| Printing color of strain relief | white |
| Sheathed cable color | black |
| Printing color of sheathed cable | white |
| Halogen-free | Yes |
| Silicon-free | Yes |
| Sheath material | Halogen-free |
| Rubber cable | No |
| Weight | 530.9 g |
| Copper weight of the raw cable | 0.12 kg/m |
Environmental requirements
| Processing temperature | -5 … +40 °C |
|---|---|
| Continuous operating temperature | -35 … +85 °C |
| Note on continuous operating temperature | Cable for temperatures ≤ 70 °C (including halogen-free)Insulating parts for temperatures ≤ 105 °C |
Commercial data
| PU (SPU) | 1 pcs |
|---|---|
| Packaging type | unpacked |
| Country of origin | DE |
| GTIN | 4055143659338 |
| Customs tariff number | 85444290900 |
Product Classification
| UNSPSC | 26121629 |
|---|---|
| eCl@ss 10.0 | 27-44-06-04 |
| eCl@ss 9.0 | 27-44-06-04 |
| ETIM 9.0 | EC002587 |
| ETIM 10.0 | EC002587 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews