Female connector/socket WINSTA® MIDI with strain reliefThe WINSTA® MIDI female connector/socket with protection against mismating supports rapid, correct installation. On PCBs, in control cabinets or for connecting lights – pluggable installation connectors from WAGO allow you to establish connections according to a huge variety of requirements in seconds. For greater security in electrical installations, the pluggable installation connector is equipped with mechanical protection against mismating. The pluggable installation connector offers protection against contact with live components in accordance with protection type IP20 (When mated and secured with a strain relief housing: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). General mains applications for almost any domain of use can be realised with WINSTA® MIDI pluggable installation connectors with A coding. This pluggable installation connector can be used for electrical currents up to 25 A. Thus the product is ideally suitable for high power loads. The WINSTA® MIDI product line achieves total flexibility for the installation. Through its Push-in CAGE CLAMP® spring pressure connection technology, it guarantees error-free, time-saving installation and offers customization for meeting all installation requirements. The strip length is 55 mm.WINSTA® MIDI solutions for your electrical installation – protected against mismating and maintenance-freeThe WINSTA® Pluggable Connection System allows pluggable electrical installation. This significantly reduces the need for servicing and lowers costs. Enjoy the benefits of the pluggable version of our maintenance-free spring pressure connection technology too! Plan your installation with with strain relief hosting from WAGO. pluggable installation connectors with protection against mismatingsimple circuitswith A coding for a large number of usescustom-engineered solutionsconvenient installation and commissioning
Specification
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60664-1 |
|---|---|
| Nominal voltage (III/3) | 400 V |
| Rated impulse withstand voltage (III / 3) | 6 kV |
| Rated current | 25 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 400 V |
| Rated impulse withstand voltage | 6 kV |
| Rated current | 25 A |
Electrical data - Ratings per UL 1977
| Note for the US market | Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office. |
|---|---|
| Rated voltage (UL 1977) | 600 V |
| Rated current UL 1977 | 23 A |
| Approvals per | UL 1977 |
| Rated voltage | 600 V |
| Rated current | 23 A |
Electrical data - General information
| Note on contact resistance | approx. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket |
|---|
Connection data
| Clamping units | 8 |
|---|---|
| Total number of potentials | 4 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
|---|---|
| Actuation type | Operating tool, Push-in |
| Nominal cross-section | 4 mm² / 12 AWG |
| Solid conductor | 0.5 … 4 mm² / 20 … 12 AWG |
| Solid conductor; push-in termination | 1.5 … 4 mm² / 16 … 12 AWG |
| Stranded conductor | 0.5 … 2.5 mm² / 20 … 14 AWG |
| Fine-stranded conductor | 0.5 … 4 mm² / 20 … 12 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5 mm² / 20 … 16 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 0.25 … 2.5 mm² / 20 … 14 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 1.5 mm² / 16 AWG |
| Strip length | 9 mm / 0.35 inches |
| Pole number | 4 |
| Conductor entry direction to mating direction | 0 ° |
| Strip length (outer insulation) | 55 mm |
Physical data
| Pin spacing | 10 mm / 0.394 inches |
|---|---|
| Width | 44.6 mm / 1.756 inches |
| Height | 17 mm / 0.669 inches |
| Depth | 76 mm / 2.992 inches |
Mechanical data
| Screw tightening torque | 0.5 Nm |
|---|---|
| Use | General mains applications |
| Coding | A |
| Variable coding | Yes |
| Marking | N ⏚ 2/L 1/L' |
| Potential marking | N ⏚ 2/L 1/L' |
| Mating force of a plug-in connection | approx. 20 … 70 N (depending on pole number) |
| Retention force of a plug-in connection | Locked: > 80 N |
| Unmating force of a plug-in connection | Unlocked: approx. 20 … 70 N (depending on pole number) |
| Number of mating cycles | 200, without resistive load |
| Protection type | IP20; When mated and secured with a strain relief housing: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!) |
Plug-in connection
| Contact type (pluggable connector) | Female connector/socket |
|---|---|
| Connector (connection type) | for conductor |
| Mismating protection | Yes |
| Note on mismating protection | All WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while rotated 180 c.) plugging while laterally staggeredd.) plugging one pole |
| Locking lever | Can be retrofitted |
| Locking of plug-in connection | locking lever |
| Note on locking system | All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug/socket). |
| Strain relief | strain relief housing |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | white |
| Cover color | gray |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Copper or copper alloy; surface-treated |
| Contact plating | Tin |
| Fire load | 0.575 MJ |
| Connector color | white |
| Strain relief color | white |
| Weight | 24.8 g |
Environmental requirements
| Processing temperature | -5 … +40 °C |
|---|---|
| Continuous operating temperature | -35 … +85 °C |
| Note on continuous operating temperature | Insulating parts for temperatures ≤ 105 °C |
Commercial data
| Product Group | 20 (Winsta) |
|---|---|
| PU (SPU) | 25 pcs |
| Packaging type | box |
| Country of origin | PL |
| GTIN | 4044918252188 |
| Customs tariff number | 85366990990 |
Product Classification
| UNSPSC | 39121402 |
|---|---|
| eCl@ss 10.0 | 27-44-06-05 |
| eCl@ss 9.0 | 27-44-06-05 |
| ETIM 9.0 | EC002560 |
| ETIM 10.0 | EC002560 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews
Clear filtersThere are no reviews yet.