Description

The intrinsically safe PROFIsafe Input Module (750-663/000-003) for functional safety provides risk reductions up to SIL 3, Cat. 4, PL e, and connects to potential-free, contact-based emergency stop switches, safety door switches, mode selectors, as well as safety sensors, that are located hazardous environments 0, 1 and 2. The fail-safe input module must be located in Zone 2.The input module features four clock-sensitive inputs (I1 … I4) that are fed by two differently clocked outputs (T1 … T2). Inputs are continually monitored for cross circuits and power supply from separate sources.Additional safety-relevant functions (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK. This configuration tool supports both CC2 and CC3 tool calling interfaces (TCI). When exchanging the module, parameters are automatically downloaded by the controller via PROFIsafe-compatible iPar server – depending on settings. The module supports both PROFIsafe V1 and V2 (PROFIBUS, PROFINET) protocols.Individual modules can be arranged in any combination within the fieldbus node’s Ex segment.

Specification

Notes

NoteThe PROFIsafe Input Module must only be operated using an Ex i 24 VDC power supply (e.g., 750-606, 750-625/000-001)! General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals! To protect the module against surge voltages (surge protection per IEC 61000-4-5), a filter module (750-626 or 750-624) or an external surge filter must be used upstream of the Ex i 24 VDC power supply. Reference the product manual for further information!

Technical data

Item descriptionIntrinsically Safe 4-Channel Digital Input; 24 VDC; PROFIsafe V 2.0 iPar
ProtocolsPROFIsafe V2
Number of digital inputs4
Total number of channels (module)4
Signal typeDigital
Signal type (voltage)24 VDC
Sensor connection4 x (Fail-safe input with test pulse)
Input characteristicclock sensitive
Input characteristicType 1 per IEC 61131
Input filter0 … 200 ms (parameterizable in steps)
Input filter: parametrizable (channel by channel)Yes
Input current per channel for signal (1) typ.3 mA
Output current per channel0.005 A
Short-circuit current≤ 25 mA
Signal frequency (max.)50 Hz
Intrinsically safe Ex iYes
Configuration optionsPROFIsafe address adjustable via DIP switch or engineering software
Supply voltage (system)5 VDC; via data contacts
Current consumption (5 V system supply)145 mA
Supply voltage (field)24 VDC; (Ex i power supply: Uo = max. 27.3 V); via power jumper contacts (supply via blade contact; distribution via spring contact)
Current consumption, field supply (module with no external load)20 mA
Power consumption P<sub>max.</sub>3 W
Power loss P<sub>l</sub>1.27 W
Isolation300 VAC system/field
IndicatorsLED (A-D) green/red: Status/Error I1 … I4; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
Number of incoming power jumper contacts2
Number of outgoing power jumper contacts2
Current carrying capacity (power jumper contacts)1 A

Functional Safety

Achievable risk reductionSIL 3 per IEC 61508; SIL 3 per IEC 61511; SIL 3 per IEC 62061; Cat. 4, PL e per EN ISO 13849
Safety standardsIEC 61508; IEC 62061; EN ISO 13849; IEC 61511

Explosion protection

IdentificationATEX: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I, IECEx/INMETRO: Ex ec IIC T4 Gc, cULus (Zone classified): Cl I Zn 2 AEx nA [ia Ga] IIC T4 Gc; Cl I Zn 2 AEx nA [ia IIIC] IIC T4 Gc; Ex nA [ia Ga] IIC T4 Gc X; Ex nA [ia IIIC] IIC T4 Gc X, cULus (Devision classified): Class I, Div. 2, Group A B C D, T4
Ex standardEN IEC 60079-0, -7, -11
Safety-relevant data (circuit)Uo = 26.8 V; Io = 22.6 mA; Po = 151 mW; linear characteristic curve
Reactances Ex ia IICLo = 69.61 mH; Co = 92 nF
Reactances Ex ia IIBLo = 278.45 mH; Co = 720 nF
Reactances Ex ia IIALo = 556.9 mH; Co = 2.37 µF
Reactances Ex ia ILo = 913.67 mH; Co = 4.2 µF
Reactances (note)Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)

Connection data

Connection technology: I/O8 x CAGE CLAMP®
Connectable conductor materialsCopper
Connection typeInputs/outputs
Solid conductor0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor0.08 … 2.5 mm² / 28 … 14 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width24 mm / 0.945 inches
Height100 mm / 3.937 inches
Depth67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail60.6 mm / 2.386 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Housing materialPolycarbonate; polyamide 6.6
Fire load1.946 MJ
Weight92 g
Conformity markingCE

Environmental requirements

Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 … 2000 m / 0 … 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, vertical top and vertical bottom
Relative humidity (without condensation)95 %
Vibration resistance4g per IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2, marine applications
EMC emission of interferenceper EN 61000-6-3, marine applications
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %10 ppm
Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %25 ppm

Commercial data

Product Group15 (I/O System)
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
Customs tariff number85389099990

Product Classification

UNSPSC32151705
eCl@ss 10.027-24-26-04
eCl@ss 9.027-24-26-04
ETIM 9.0EC001599
ETIM 10.0EC001599
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 75980-60-8, 80-05-7
REACH Candidate List Substance4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide, Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)455422aa-0af7-4236-bce5-56a64061e77a
SCIP notification number (Belgium)d08aa233-6cb6-41d9-a0bc-f32f7a9c1388
SCIP notification number (Bulgaria)5e00a515-53cf-4b0f-b72e-d849e2b82d4d
SCIP notification number (Czech Republic)297355ca-ec16-4ed8-96d9-46703f222b73
SCIP notification number (Denmark)a5c890cd-d642-467f-ad02-01fc6bd03c89
SCIP notification number (Finland)bc722cdd-62f7-4cb5-a606-7bd2aebdff8a
SCIP notification number (France)c3eec32c-a4c6-4661-a4ed-1bd4e9cec74a
SCIP notification number (Germany)1d5a8811-eed2-488d-bed9-fa61f31ce19b
SCIP notification number (Hungary)caf38cc2-d5a8-4317-b257-09a4814898f5
SCIP notification number (Italy)a6ec395a-a99f-4b96-b6f3-ac92b6b9eac3
SCIP notification number (Netherlands)60969300-4247-46b1-af2c-2d7bdf58a56a
SCIP notification number (Poland)5018c2ce-0c5c-4115-bc62-41290fdb653e
SCIP notification number (Romania)df068cd7-6fb3-4b09-9e10-1f9e1189b9d8
SCIP notification number (Sweden)47f6856c-9e40-4127-8008-6375a41117e0

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 750-663/000-003”

Your email address will not be published. Required fields are marked *