Wago 294-8335

Field-wiring terminal block with linect<sup>®</sup>, 294 Series, Push-inOur field-wiring terminal block with linect<sup>®</sup> (item number 294-8335) simplifies electrical ins…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Field-wiring terminal block with linect<sup>®</sup>, 294 Series, Push-inOur field-wiring terminal block with linect<sup>®</sup> (item number 294-8335) simplifies electrical installations. Conductors can only be connected to field-wiring terminal block with linect<sup>®</sup> if their strip length is between 8 and 9 mm . This product features four conductor terminals and utilizes Push-in CAGE CLAMP® as well as PUSH WIRE®. Push-in CAGE CLAMP® technology provides a universal connection solution for all conductor types. It allows both solid and fine-stranded conductors with ferrules to be inserted directly into the clamping point without the need for tools. Our PUSH WIRE® connection uses the stiffness of the conductor to overcome the clamping spring’s contact force, allowing faster and easier conductor clamping. The item’s dimensions are (50 x 22.4 x 27.3) mm (width x height x depth). Depending on the conductor type, field-wiring terminal block with linect<sup>®</sup> is designed for conductor cross sections ranging from 0.5 mm² to 2.5 mm² on one side and for conductor cross sections from 0.5 mm² to 2.5 mm² on the other side as well as conductor cross sections from 0.5 mm² to 1.5 mm² and from 0.5 mm² to 0.75 mm².The contact surface is coated with tin.

Specification

Electrical data - Ratings per IEC/EN

RatingsConnection points
Ratings perIEC/EN 60998-1
Nominal voltage (II/2)500 V
Rated impulse withstand voltage (II/2)4 kV
Rated current24 A
Legend (ratings)(II / 2) ≙ Overvoltage category II / Pollution degree 2
RatingsConnection points / Connection points / Connection points
Ratings perIEC/EN 60998-1 / IEC/EN 60998-1 / IEC/EN 60998-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage500 V
Rated impulse withstand voltage4 kV
Rated current24 A

Electrical data - Ratings per IEC/EN 2

RatingsConnection points
Ratings perIEC/EN 60998-2-2
Rated voltage (II/2)500 V
Rated impulse withstand voltage (II/2)4 kV
Rated current24 A
RatingsConnection points / Connection points / Connection points
Ratings perIEC/EN 60998-2-2 / IEC/EN 60998-2-2 / IEC/EN 60998-2-2
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage500 V
Rated impulse withstand voltage4 kV
Rated current24 A

Electrical data - Ratings per IEC/EN 3

RatingsLinect® plug-in connection
Ratings perIEC/EN 61984
Rated voltage (II/2)500 V
Rated impulse withstand voltage (II/2)4 kV
Rated current16 A
RatingsLinect® plug-in connection / Linect® plug-in connection / Linect® plug-in connection
Ratings perIEC/EN 61984 / IEC/EN 61984 / IEC/EN 61984
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage500 V
Rated impulse withstand voltage4 kV
Rated current16 A

Connection data

Total number of potentials5
Number of connection types4
PE functionAngled snap-in PE contact

Connection data - Connection 1

Connection typeExternal 1
Connection technologyPush-in CAGE CLAMP®
Number of connection points2
Actuation typePush-button
Solid conductor0.5 … 2.5 mm² / 18 … 12 AWG
Solid conductor; push-in termination0.5 … 2.5 mm² / 18 … 12 AWG
Stranded conductor0.5 … 2.5 mm² / 18 … 14 AWG
Fine-stranded conductor0.5 … 2.5 mm² / 18 … 14 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 1.5 mm² / 18 … 16 AWG
Fine-stranded conductor; with uninsulated ferrule0.5 … 1.5 mm² / 18 … 16 AWG
Fine-stranded conductor; with ferrule; push-in termination0.5 mm² / 18 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches
Pole number5

Connection data - Connection 2

Connection typeInternal 2
Connection technologyPUSH WIRE®
Number of connection points1
Actuation typePush-in
Solid conductor0.5 … 2.5 mm² / 18 … 14 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 1 mm² / 18 … 14 AWG
Fine-stranded conductor; with uninsulated ferrule0.5 … 1.5 mm² / 18 … 16 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches

Connection data - Connection 3

Connection typeInternal 3
Connection technologyPUSH WIRE®
Number of connection points1
Actuation typePush-in
Solid conductor0.5 … 1.5 mm² / 18 … 16 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 0.75 mm² / 18 AWG
Fine-stranded conductor; with uninsulated ferrule0.5 … 1 mm² / 18 … 14 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches

Connection data - Connection 4

Connection typeInternal 4
Connection technologyPUSH WIRE®
Number of connection points1
Actuation typePush-in
Solid conductor0.5 … 0.75 mm² / 18 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches

Physical data

Pin spacing10 mm / 0.394 inches
Width50 mm / 1.969 inches
Height22.4 mm / 0.882 inches
Height from the surface17 mm / 0.669 inches
Depth27.3 mm / 1.075 inches

Mechanical data

TechnologyLinect
MarkingDA+ DA- L ⏚ N

Material data

Note (material data)Information on material specifications can be found here
Colorwhite
Material groupIIIa
Insulation material (main housing)Polycarbonate (PC)
Flammability class per UL94V0
Clamping spring materialChrome-nickel spring steel (CrNi)
Contact materialElectrolytic copper (ECu)
Contact platingTin
Fire load0.332 MJ
Weight17.1 g

Environmental requirements

Temperature stability120 °C
T markingT85

Commercial data

Product Group8 (Misc. Chassis Mount Blocks)
PU (SPU)250 pcs
Packaging typebag
Country of originPL
GTIN4050821098911
Customs tariff number85369010000

Product Classification

UNSPSC39121409
eCl@ss 10.027-14-11-06
eCl@ss 9.027-14-11-06
ETIM 9.0EC001284
ETIM 10.0EC001284
ECCNNO US CLASSIFICATION

Environmental Product Compliance

REACH Candidate List SubstancePerfluorobutane sulfonic acid (PFBS) and its salts
RoHS Compliance StatusCompliant,No Exemption
SCIP notification number (Austria)b51c5d30-4871-4d2e-a482-8e2d9923e58d
SCIP notification number (Belgium)61a684a2-4556-4d53-b43f-8e406897d1ab
SCIP notification number (Bulgaria)6e5d9df2-14e4-4fd2-a388-ac37486bd818
SCIP notification number (Czech Republic)40990f82-93a8-42d3-bd8a-639fcf0db3ee
SCIP notification number (Denmark)e5d25401-4c38-49e2-9952-370f3548a116
SCIP notification number (Finland)6f419b02-b0c1-4729-a281-9fbf3aaba88a
SCIP notification number (France)ac5591da-c0fe-4cee-a7ff-d4a3c6aa9ed4
SCIP notification number (Germany)15c0e06b-bdc8-46ad-826a-179522061552
SCIP notification number (Hungary)addb71cf-da0a-4a1b-8eb6-7b7be81549f4
SCIP notification number (Italy)45aa505c-c0ac-468c-a14f-077042620475
SCIP notification number (Netherlands)95fcad68-8e1e-4bb3-9196-428d38ae545c
SCIP notification number (Poland)e67fe194-1126-4254-9332-870783503d9e
SCIP notification number (Romania)dd7654e2-8963-40a4-b74d-ddfa3f0a6ba8
SCIP notification number (Sweden)87e941b2-96d2-4189-8d2d-8bc1bc3802f0

Other

TechnologyLinect