Fast delivery within 72 Hours

Wago 2857-533/000-001

Short description:WAGO’s RTD threshold value switch for RTD sensors, potentiometers and resistors monitors and reports signals for up to two switching thresholds.Features:Both digital signal output an…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Short description:WAGO’s RTD threshold value switch for RTD sensors, potentiometers and resistors monitors and reports signals for up to two switching thresholds.Features:Both digital signal output and relay with make contact react to configured measurement range limits (on/off switching delay and threshold value switch function can be configured with up to two threshold values)Configurable RTD factorAdjustable software filterSafe three-way isolation with 4 kV test voltage per EN 61010-1For railway applications

Specification

Notes

NoteThis product is powered by 24 VDC, which can be bridged using lateral push-in type jumper bars: (6.1) US+ (BR) and (6.2) GND 2 (BR). With this variant, it is important to ensure that the maximum permissible total current of 2 A is not exceeded.

Technical data - Configuration

Configuration optionsWAGO Interface Configuration Software

Technical data - Input

Input signal typePotentiometer, Resistance, RTD sensors, Potentiometers, Resistor

Technical data - Input (RTD sensors)

Sensor types (RTD)Pt100, Pt200, Pt500, Pt1000, Pt5000, Pt10000, Pt10 … Pt20000
Sensor connection2-wire; 3-wire; 4-wire; differential
Sensor power supply (RTD) max.≤ 0.5 mA
Temperature measurement range (RTD)−200 … +850 °C

Technical data - Input (resistors)

Input range (resistor)0 … 100 kΩ
Input range (potentiometer)0 … 100 kΩ

Technical data - Output (digital)

Switching voltage (DO) max.Applied supply voltage − 0.3 V
Continuous current (DO) max.100 mA (no internal restriction)
Number of switching thresholds (DO)1 or 2 (adjustable)
Configurable rise/fall delay time (DO)0 … 60 s (via software)

Technical data - Output (relay)

Number of make/switch-on contacts1
Contact material (relay)AgNi + Au
Switching Voltage, Max.250 VAC
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Pull-in time (typ.)8 ms
Drop-out time (typ.)4 ms
Bounce time (typ.)8 ms
Number of switching thresholds (relay)1 or 2 (adjustable)
Configurable rise/fall delay time (relay)0 … 60 s (via software)
Continuous current (max.)6 A

Technical data - Signal processing

Software filter (adjustable)Moving average value (filter level: 30)
Step response (typ.)60 ms (2-wire), 360 ms (3-wire), 540 ms (4-wire), 360 ms (potentiometer)

Technical data - Measurement error

Transmission error (max.)± 1 K
Temperature coefficient≤ 0.01 %/K

Technical data - Power supply

Power supply type24 VDC
Nominal supply voltage U<sub>S</sub>24 VDC (SELV)
Supply voltage range±30 %
Current consumption at nominal supply voltage≤ 40 mA (+ IDO)

Safety and protection

Rated voltage300 V
Rated voltage of the measurement circuit connections per EN 61010-2-030AC 300 V
Note on insulation parametersTemperature sensors must not be used in hazardous circuits unless the external temperature sensors used provide basic insulation in accordance with EN 61010-1 (300 VAC; Overvoltage Category II; Pollution Degree 2). The digital output (DO) operates at the supply potential.
Protection typeIP20

Safety and protection - Test voltage

Test voltage (input/relay output/supply)4 kVAC; 60 Hz; 1 min
Test voltage (input/service interface)3 kVAC; 60 Hz; 1 min
Test voltage (relay output/service interface)4 kVAC; 60 Hz; 1 min
Test voltage (supply/service interface)2.5 kVAC; 60 Hz; 1 min

Safety and protection - Insulation coordination

Overvoltage categoryII
Pollution degree2
Insulation type (input, supply and service interface/relay output)Reinforced insulation (safe isolation)
Insulation type (input/supply/service interface)Basic insulation

Connection data

Connection technologyPush-in CAGE CLAMP®
WAGO connectorpicoMAX® 5.0
Solid conductor0.2 … 2.5 mm² / 24 … 12 AWG
Fine-stranded conductor0.2 … 2.5 mm² / 24 … 12 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width12.5 mm / 0.492 inches
Height110 mm / 4.331 inches
Depth from upper-edge of DIN-rail107 mm / 4.213 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Fire load1.556 MJ
Weight85.9 g

Environmental requirements

Ambient temperature (operation)-40 … +70 °C
Ambient temperature (storage)-40 … +85 °C
Temperature range of connection cable≥ (Tambient + 30 K)
Relative humidity5 … 95 %
Operating altitude (max.)2000 m

Environmental requirements - Environmental conditions per DIN EN 50155:2018-05

AltitudeA1
Operating temperature classOT3
Extended operating temperature at switch-onST1
Quick temperature changesH1
Power supply interruptionsS1
Switching classes (power supply)C2
Service lifeL4 at 40 °C (max.)
Protective coatings for populated PCBsPC2
Temporary supply voltage dipsCriterion B

Standards and specifications

Conformity markingCE
EMC immunity to interferenceEN 61000-6-2; EN 61326-2-3; EN 50121-3-2
EMC emission of interferenceEN 61000-6-4; EN 61326-2-3; EN 50121-3-2
Standards/specificationsEN 61010-1, EN 61373, EN 50121-3-2

Commercial data

PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4066966390032
Customs tariff number90303370000

Product Classification

UNSPSC39122334
ETIM 9.0EC001446
ETIM 10.0EC001446
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 75980-60-8, 79-94-7
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide, Perfluorobutane sulfonic acid (PFBS) and its salts, Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)a1f6ebca-6ee1-4502-97a0-ca81287a2bc9
SCIP notification number (Belgium)807f8a01-2e4d-4e0c-9c71-6e8338955d40
SCIP notification number (Bulgaria)3d3329a0-3e66-4ce8-ac33-2dffabba9970
SCIP notification number (Czech Republic)b7d1b66f-7f24-48b2-9f05-050931d626dd
SCIP notification number (Denmark)ec5d7e12-0adb-4474-ada9-a2ff1e97e937
SCIP notification number (Finland)7712a94a-787d-4297-b7d7-99327420f870
SCIP notification number (France)101b3e36-3f6c-4e3a-bf08-2627108fd00e
SCIP notification number (Germany)4c6d0c05-9dbb-4306-ac2a-42c80ad0a306
SCIP notification number (Hungary)da7cf922-0be7-4349-8719-d225e789f331
SCIP notification number (Italy)8b1e792f-6a2e-492e-ac79-206646d7cd82
SCIP notification number (Netherlands)89b20b14-a048-4891-9e45-48a30fd47426
SCIP notification number (Poland)155b9aa7-ace0-4176-92f0-6fc03a3c598e
SCIP notification number (Romania)1c695032-aee4-4e17-8776-0b012226ff2b
SCIP notification number (Sweden)509681b7-8017-48ab-8a20-b7682857049f

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 2857-533/000-001”

Your email address will not be published. Required fields are marked *