Through terminal block, 2250 Series, Push-in CAGE CLAMP®Quick and easy connections are guaranteed with this through terminal block (item number 2250-1205). Conductors can only be connected to this through terminal block if their strip length is between 9 and 11 mm . Our mini rail-mount terminal blocks are perfect for working in small spaces thanks to their compact design. With various mounting and actuation options, they offer complete flexibility. This product features conductor terminals and utilizes Push-in CAGE CLAMP®. Push-in CAGE CLAMP® technology provides a universal connection solution for all conductor types. It allows both solid and fine-stranded conductors with ferrules to be inserted directly into the clamping point without the need for tools. Depending on the type of conductor, this through terminal block is suitable for conductor cross sections ranging from 0.14 mm² to 1.5 mm².This mini rail-mount terminal block is operated with a push-button. Our TOPJOB® S rail-mount terminal blocks are perfect for a wide range of industrial applications and modern building installations thanks to the secure electrical connections they provide. You can work anywhere in the world and on any application with just a single rail-mount terminal block system. This product is designed for specific Ex applications (please refer to the product datasheet).
Specification
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60947-7-1 |
|---|---|
| Nominal voltage (III/3) | 500 V |
| Rated impulse withstand voltage (III / 3) | 6 kV |
| Rated current | 13.5 A |
| Current at conductor cross-section (max.) mm² | 17.5 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 500 V |
| Rated impulse withstand voltage | 6 kV |
| Rated current | 13.5 A |
| Current at conductor cross-section (max.) mm² | 17.5 A |
Electrical data - Ratings per UL
| Approvals per | UL 1059 |
|---|---|
| Rated voltage UL (Use Group B) | 300 V |
| Rated current UL (Use Group B) | 10 A |
| Rated voltage UL (Use Group C) | 300 V |
| Rated current UL (Use Group C) | 10 A |
| Approvals per | UL 1059 / UL 1059 / UL 1059 |
| Use group | B / C / D |
| Rated voltage | 300 V / 300 V |
| Rated current | 10 A / 10 A |
Electrical data - Ratings per CSA
| Approvals per | CSA 22.2 No 158 |
|---|---|
| Rated voltage CSA (Use Group B) | 300 V |
| Rated current CSA (Use Group B) | 10 A |
| Rated voltage CSA (Use Group C) | 300 V |
| Rated current CSA (Use Group C) | 10 A |
| Approvals per | CSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158 |
| Use group | B / C / D |
| Rated voltage | 300 V / 300 V |
| Rated current | 10 A / 10 A |
Electrical data - Ex information
| Reference to hazardous areas | See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications” |
|---|---|
| Ratings per | ATEX: PTB 19 ATEX 1019 U / IECEx: PTB 19.0050U (Ex eb IIC Gb) |
| Rated voltage EN (Ex e II) | 352 V |
| Rated current (Ex e II) | 13.5 A |
| Rated current (Ex e II) with jumper | 12 A |
Electrical data - Power Loss
| Rated current I<sub>N</sub> for power loss specification | 13.5 A |
|---|---|
| Resistance value for specified, current-dependent power loss | 0.002 Ω |
Electrical data - General information
| Wiring direction | Front-entry wiring |
|---|
Connection data
| Clamping units | 2 |
|---|---|
| Total number of potentials | 1 |
| Number of levels | 1 |
| Number of jumper slots | 1 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
|---|---|
| Actuation type | Push-button |
| Connectable conductor materials | Copper |
| Nominal cross-section | 1 mm² |
| Solid conductor | 0.14 … 1.5 mm² / 24 … 16 AWG |
| Solid conductor; push-in termination | 0.5 … 1.5 mm² / 20 … 16 AWG |
| Fine-stranded conductor | 0.14 … 1.5 mm² / 24 … 16 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.14 … 1 mm² / 24 … 18 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 0.14 … 1 mm² / 24 … 18 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 0.5 … 1 mm² / 20 … 18 AWG |
| Note (conductor cross-section) | Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. |
| Strip length | 9 … 11 mm / 0.35 … 0.43 inches |
| Wiring direction | Front-entry wiring |
Physical data
| Width | 3.5 mm / 0.138 inches |
|---|---|
| Height | 34.1 mm / 1.343 inches |
| Depth from upper-edge of DIN-rail | 27.9 mm / 1.098 inches |
Mechanical data
| Mounting type | DIN-15 rail |
|---|---|
| Marking level | Center/side marking |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | black |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 0.066 MJ |
| Weight | 2.4 g |
Environmental requirements
| Processing temperature | -35 … +85 °C |
|---|---|
| Continuous operating temperature | -60 … +105 °C |
Commercial data
| PU (SPU) | 100 pcs |
|---|---|
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4066966309416 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121410 |
|---|---|
| ETIM 9.0 | EC000897 |
| ETIM 10.0 | EC000897 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews