Fast delivery within 72 Hours

Wago 2206-8032

Distribution terminal block, 2206 Series, push-buttonFault-free electrical installations are guaranteed with this distribution terminal block (item number 2206-8032). Ensure that the strip lengths are…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Distribution terminal block, 2206 Series, push-buttonFault-free electrical installations are guaranteed with this distribution terminal block (item number 2206-8032). Ensure that the strip lengths are between 13 and 15 mm  when connecting conductors to this distribution terminal block. Distribution terminal blocks allow you to distribute potentials with a single extremely compact terminal block. Their design also means you can connect larger conductor cross-sections on one side and several smaller conductor cross-sections on the other. Aside from potential distribution, these terminal blocks can also be used for potential collection. This product incorporates conductor terminals and utilizes Push-in CAGE CLAMP® and Push-in CAGE CLAMP®. Our Push-in CAGE CLAMP® is a universal, maintenance-free connection solution for all conductor types, offering a key advantage: It allows direct insertion of both solid and fine-stranded conductors with ferrules without needing tools. No preparation is required; for example, crimping the conductor’s ferrule is not necessary. This distribution terminal block is suitable for conductor cross sections ranging from 0.5 mm² to 10 mm² on one side and for conductor cross sections ranging from 0.25 mm² to 2.5 mm² on the other side.Tin is used for coating the contact surfaces. A push-button is used to operate this through rail-mount terminal block. Our TOPJOB® S rail-mount terminal blocks offer more than just secure electrical connections in a range of different industrial applications and modern building installations. They also offer the perfect actuation variant for every need: lever, push-button, or operating slot. This product is designed for specific Ex applications (please refer to the product datasheet).

Specification

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60664-1
Nominal voltage (III/3)800 V
Rated impulse withstand voltage (III / 3)8 kV
Rated current41 A
Current at conductor cross-section (max.) mm²57 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage800 V
Rated impulse withstand voltage8 kV
Rated current41 A
Current at conductor cross-section (max.) mm²57 A

Electrical data - Power Loss

Power loss, per pole (potential)1.311 W
Rated current I<sub>N</sub> for power loss specification41 A
Resistance value for specified, current-dependent power loss0.001 Ω

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Clamping units7
Total number of potentials1
Number of levels1

Connection data - Connection 1

Connection typeInput
Connection technologyPush-in CAGE CLAMP®
Number of connection points1
Actuation typePush-button
Connectable conductor materialsCopper
Nominal cross-section6 mm²
Solid conductor0.5 … 10 mm² / 20 … 8 AWG
Solid conductor; push-in termination2.5 … 10 mm² / 14 … 8 AWG
Fine-stranded conductor0.5 … 10 mm² / 20 … 8 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 6 mm² / 20 … 10 AWG
Fine-stranded conductor; with ferrule; push-in termination2.5 … 6 mm² / 16 … 10 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length13 … 15 mm / 0.51 … 0.59 inches
Wiring directionFront-entry wiring

Connection data - Connection 2

Connection typeOutput
Connection technologyPush-in CAGE CLAMP®
Number of connection points6
Nominal cross-section1.5 mm²
Solid conductor0.25 … 2.5 mm² / 22 … 14 AWG
Solid conductor; push-in termination0.75 … 2.5 mm² / 18 … 14 AWG
Fine-stranded conductor0.25 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor; with insulated ferrule0.25 … 1.5 mm² / 22 … 16 AWG
Fine-stranded conductor; with ferrule; push-in termination0.75 … 1.5 mm² / 18 … 16 AWG
Strip length9 … 11 mm / 0.35 … 0.43 inches

Physical data

Width9 mm / 0.354 inches
Height73.8 mm / 2.905 inches
Depth from upper-edge of DIN-rail32.9 mm / 1.295 inches

Mechanical data

Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colororange
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Clamping spring materialChrome-nickel spring steel (CrNi)
Contact platingTin
Fire load0.367 MJ
Actuator colororange
Weight16.3 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

PU (SPU)12 pcs
Packaging typeBox
Country of originDE
GTIN4066966379112
Customs tariff number85369010000

Product Classification

UNSPSC39121410
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 2206-8032”

Your email address will not be published. Required fields are marked *