Power distribution disconnect terminal block, 2206 Series, Push-in CAGE CLAMP®Seamless electrical installations are guaranteed with this power distribution disconnect terminal block (item number 2206-7111). Strip lengths must be between 13 and 15 mm when connecting conductors to this power distribution disconnect terminal block. This product incorporates conductor terminals and utilizes Push-in CAGE CLAMP®. Push-in CAGE CLAMP® technology provides a universal connection solution for any type of conductor. It allows both solid and fine-stranded conductors with ferrules to be inserted directly into the clamping point without the need for tools. Depending on the type of conductor, this power distribution disconnect terminal block is designed for conductor cross sections ranging from 0.5 mm² to 10 mm².
Specification
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60947-7-1 |
|---|---|
| Nominal voltage (III/3) | 250 V |
| Rated impulse withstand voltage (III / 3) | 4 kV |
| Rated current | 41 A |
| Current at conductor cross-section (max.) mm² | 51 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 250 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 41 A |
| Current at conductor cross-section (max.) mm² | 51 A |
Electrical data - Power Loss
| Power loss, per pole (potential) | 2.029 W |
|---|---|
| Rated current I<sub>N</sub> for power loss specification | 51 A |
Electrical data - General information
| Wiring direction | Front-entry wiring |
|---|
Connection data
| Clamping units | 1 |
|---|---|
| Total number of potentials | 1 |
| Number of levels | 1 |
| Number of jumper slots | 2 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
|---|---|
| Actuation type | Push-button |
| Connectable conductor materials | Copper |
| Nominal cross-section | 6 mm² |
| Solid conductor | 0.5 … 10 mm² / 20 … 8 AWG |
| Solid conductor; push-in termination | 2.5 … 10 mm² / 14 … 8 AWG |
| Fine-stranded conductor | 0.5 … 10 mm² / 20 … 8 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.5 … 6 mm² / 20 … 10 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 2.5 … 6 mm² / 16 … 10 AWG |
| Note (conductor cross-section) | Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. |
| Strip length | 13 … 15 mm / 0.51 … 0.59 inches |
| Wiring direction | Front-entry wiring |
Physical data
| Width | 7.5 mm / 0.295 inches |
|---|---|
| Height | 60.1 mm / 2.366 inches |
| Depth from upper-edge of DIN-rail | 38.1 mm / 1.5 inches |
Mechanical data
| Mounting type | DIN-35 rail |
|---|---|
| Marking level | Center/side marking |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | gray |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 0.227 MJ |
| Weight | 14.4 g |
Environmental requirements
| Processing temperature | -35 … +60 °C |
|---|---|
| Continuous operating temperature | -60 … +105 °C |
Environmental requirements - Environmental Testing
| Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
|---|---|
| Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
| Spectrum/Mounting location | Service life test, Category 1, Class A/B |
| Functional test with noise-like oscillations | Test passed according to Section 8 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.101g (highest test level used for all axes) |
| Test duration per axis | 10 min. |
| Test directions | X, Y and Z axes |
| Monitoring of contact faults and interruptions | Passed |
| Voltage drop measurement before and after each axis | Passed |
| Simulated service life test through increased levels of noise-like oscillations | Test passed according to Section 9 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.572g (highest test level used for all axes) |
| Test duration per axis | 5 h |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Shock test | Test passed according to Section 10 of the standard |
| Shock pulse form | Half sine |
| Acceleration | 5g (highest test level used for all axes) |
| Shock duration | 30 ms |
| Number of shocks (per axis) | 3 pos. und 3 neg. |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Vibration and shock stress for rolling stock equipment | Passed |
Commercial data
| PU (SPU) | 50 pcs |
|---|---|
| Packaging type | Box |
| Country of origin | PL |
| GTIN | 4066966319019 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121410 |
|---|---|
| ETIM 9.0 | EC001257 |
| ETIM 10.0 | EC001257 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|