Fast delivery within 72 Hours

Wago 2206-1201

Through terminal block, 2206 Series, grayQuick and easy connections are guaranteed with this through terminal block (item number 2206-1201). Ensure that the strip lengths are between 13 and 15 mm  whe…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Through terminal block, 2206 Series, grayQuick and easy connections are guaranteed with this through terminal block (item number 2206-1201). Ensure that the strip lengths are between 13 and 15 mm  when connecting conductors to this through terminal block. Whether for use in industry or building installations, our rail-mount through terminal blocks allow you to quickly and securely connect electrical conductors. They’re perfect for either classic through-wiring or distributing potential, depending on the variant. Featuring conductor terminals along with Push-in CAGE CLAMP®, this connector is highly versatile. Our Push-in CAGE CLAMP® is a universal, maintenance-free connection solution for all conductor types, featuring a winning design: both solid and fine-stranded conductors with ferrules can be directly inserted without the need for tools or any preparation, such as crimping the ferrule. The dimensions are (7.5 x 57.3 x 39.5) mm (width x height x depth). Depending on the type of conductor, this through terminal block is designed for conductor cross sections ranging from 0.5 mm² to 10 mm².This through rail-mount terminal block is operated with a push-button. Our TOPJOB® S rail-mount terminal blocks offer more than just secure electrical connections in various industrial applications and modern building installations. They also offer the perfect solution for every use: lever, push-button, or operating slot. This product is designed for specific Ex applications (please refer to the product datasheet).

Specification

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60947-7-1
Nominal voltage (III/3)800 V
Rated impulse withstand voltage (III / 3)8 kV
Rated current41 A
Current at conductor cross-section (max.) mm²57 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage800 V
Rated impulse withstand voltage8 kV
Rated current41 A
Current at conductor cross-section (max.) mm²57 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)600 V
Rated current UL (Use Group B)50 A
Rated voltage UL (Use Group C)600 V
Rated current UL (Use Group C)50 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current50 A / 50 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated voltage CSA (Use Group B)600 V
Rated current CSA (Use Group B)50 A
Rated voltage CSA (Use Group C)600 V
Rated current CSA (Use Group C)50 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current50 A / 50 A

Electrical data - Ex information

Reference to hazardous areasSee “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
Ratings perATEX: PTB 18 ATEX 1007 U / IECEx: PTB 18.0014U
Rated voltage EN (Ex e II)550 V
Rated current (Ex e II)41 A
Rated current (Ex e II) with jumper33 A

Electrical data - Power Loss

Power loss, per pole (potential)0.799 W
Rated current I<sub>N</sub> for power loss specification41 A
Resistance value for specified, current-dependent power loss0.001 Ω

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Clamping units2
Total number of potentials1
Number of levels1
Number of jumper slots2

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typePush-button
Connectable conductor materialsCopper
Nominal cross-section6 mm²
Solid conductor0.5 … 10 mm² / 20 … 8 AWG
Solid conductor; push-in termination1 … 10 mm² / 14 … 8 AWG
Fine-stranded conductor0.5 … 10 mm² / 20 … 8 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 6 mm² / 20 … 10 AWG
Fine-stranded conductor; with ferrule; push-in termination2.5 … 6 mm² / 16 … 10 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length13 … 15 mm / 0.51 … 0.59 inches
Wiring directionFront-entry wiring

Physical data

Width7.5 mm / 0.295 inches
Height57.3 mm / 2.256 inches
Depth from upper-edge of DIN-rail32.9 mm / 1.295 inches
Depth39.5 mm / 1.555 inches

Mechanical data

Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.202 MJ
Actuator colororange
Weight10 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

PU (SPU)50 pcs
Packaging typebox
Country of originDE
GTIN4055143846615
Customs tariff number85369010000

Product Classification

UNSPSC39121410
eCl@ss 10.027-14-11-20
eCl@ss 9.027-14-11-20
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 2206-1201”

Your email address will not be published. Required fields are marked *