Fast delivery within 72 Hours
Wago 2016-1208
Shield terminal block, 2016 Series, operating toolOur shield terminal block (item number 2016-1208) ensures effortless electrical installations. Conductors should only be connected to this shield term…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Shield terminal block, 2016 Series, operating toolOur shield terminal block (item number 2016-1208) ensures effortless electrical installations. Conductors should only be connected to this shield terminal block if their strip length is between 18 and 20 mm . By connecting to the mounting rail via an integrated contact foot, shield terminal blocks provide a reliable electrical and mechanical connection between electrical conductors and the mounting adapter. This allows them to suppress interference signals and ensure high signal quality. Featuring conductor terminals along with Push-in CAGE CLAMP®, this connector delivers reliable performance. Our Push-in CAGE CLAMP® is a universal, maintenance-free connection solution for all conductor types, featuring a winning design: both solid and fine-stranded conductors with ferrules can be directly inserted without the need for tools or any preparation, such as crimping the ferrule. This shield terminal block is suitable for conductor cross sections ranging from 0.5 mm² to 16 mm².This through rail-mount terminal block is operated with an operating tool. Our TOPJOB® S rail-mount terminal blocks guarantee secure electrical connections across many industrial applications and modern building installations. They make wiring work easier as you can quickly plug in solid, stranded, and fine-stranded conductors with ferrules.
Specification
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60947-7-2 |
|---|---|
| Ratings per | IEC/EN 60947-7-2 / IEC/EN 60947-7-2 / IEC/EN 60947-7-2 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
Electrical data - Ratings per IEC/EN – Notes
| Rated current (note) | 15 mm high DIN-35 rails shall be used for a current load higher than 76 A! |
|---|
Electrical data - General information
| Wiring direction | Front-entry wiring |
|---|
Connection data
| Clamping units | 2 |
|---|---|
| Total number of potentials | 1 |
| Number of levels | 1 |
| Number of jumper slots | 2 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
|---|---|
| Actuation type | Operating tool |
| Connectable conductor materials | Copper |
| Nominal cross-section | 16 mm² |
| Solid conductor | 0.5 … 16 mm² / 20 … 6 AWG |
| Solid conductor; push-in termination | 6 … 16 mm² / 14 … 6 AWG |
| Fine-stranded conductor | 0.5 … 25 mm² / 20 … 4 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.5 … 16 mm² / 20 … 6 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 6 … 16 mm² / 10 … 6 AWG |
| Note (conductor cross-section) | Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. AWG specifications were converted according to IEC. |
| Strip length | 18 … 20 mm / 0.71 … 0.79 inches |
| Wiring direction | Front-entry wiring |
Physical data
| Width | 12 mm / 0.472 inches |
|---|---|
| Height | 69.8 mm / 2.748 inches |
| Depth from upper-edge of DIN-rail | 36.9 mm / 1.453 inches |
Mechanical data
| Mounting type | DIN-35 rail |
|---|---|
| Marking level | Center/side marking |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | white |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 0.282 MJ |
| Weight | 36.3 g |
Environmental requirements
| Processing temperature | -35 … +85 °C |
|---|---|
| Continuous operating temperature | -60 … +105 °C |
Environmental requirements - Environmental Testing
| Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
|---|---|
| Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
| Spectrum/Mounting location | Service life test, Category 1, Class A/B |
| Functional test with noise-like oscillations | Test passed according to Section 8 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.101g (highest test level used for all axes) |
| Test duration per axis | 10 min. |
| Test directions | X, Y and Z axes |
| Monitoring of contact faults and interruptions | Passed |
| Voltage drop measurement before and after each axis | Passed |
| Simulated service life test through increased levels of noise-like oscillations | Test passed according to Section 9 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.572g (highest test level used for all axes) |
| Test duration per axis | 5 h |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Shock test | Test passed according to Section 10 of the standard |
| Shock pulse form | Half sine |
| Acceleration | 5g (highest test level used for all axes) |
| Shock duration | 30 ms |
| Number of shocks (per axis) | 3 pos. und 3 neg. |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Vibration and shock stress for rolling stock equipment | Passed |
Commercial data
| Product Group | 22 (TOPJOB S) |
|---|---|
| PU (SPU) | 20 pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4050821193739 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121410 |
|---|---|
| eCl@ss 10.0 | 27-14-11-41 |
| eCl@ss 9.0 | 27-14-11-41 |
| ETIM 9.0 | EC000901 |
| ETIM 10.0 | EC000901 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews