Description

Through terminal block, 2016 Series, operating toolConnect conductors quickly and safely with this through terminal block (item number 2016-1203). Strip lengths must be between 18 and 20 mm  when connecting conductors to this through terminal block. Whether for industrial or building applications, you can use our through terminal blocks to connect electrical conductors quickly and safely. We offer variants for both classic through-wiring and potential distribution. This product incorporates conductor terminals and utilizes Push-in CAGE CLAMP®. Push-in CAGE CLAMP® connection technology is ideal for connecting all conductor types. Solid and fine-stranded conductors with ferrules can be inserted without needing to use any tools—all thanks to its pluggable design. The item’s dimensions are (12 x 69.8 x 43.5) mm (width x height x depth). This through terminal block is suitable for conductor cross sections ranging from 0.5 mm² to 16 mm².An operating tool is used to operate this through rail-mount terminal block. Our TOPJOB® S rail-mount terminal blocks are perfect for a wide range of industrial applications and modern building installations as they ensure secure electrical connections. You can work anywhere in the world and on any application with just a single rail-mount terminal block system. This product is designed for specific Ex applications (please refer to the product datasheet).

Specification

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60947-7-1
Nominal voltage (III/3)800 V
Rated impulse withstand voltage (III / 3)8 kV
Rated current76 A
Current at conductor cross-section (max.) mm²90 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage800 V
Rated impulse withstand voltage8 kV
Rated current76 A
Current at conductor cross-section (max.) mm²90 A

Electrical data - Ratings per IEC/EN – Notes

Rated current (note)15 mm high DIN-35 rails shall be used for a current load higher than 76 A!

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)600 V
Rated current UL (Use Group B)85 A
Rated voltage UL (Use Group C)600 V
Rated current UL (Use Group C)85 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current85 A / 85 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated voltage CSA (Use Group B)600 V
Rated current CSA (Use Group B)80 A
Rated voltage CSA (Use Group C)600 V
Rated current CSA (Use Group C)80 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current80 A / 80 A

Electrical data - Ex information

Reference to hazardous areasSee application instructions in section “Knowledge and Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
Ratings perATEX: PTB 05 ATEX 1031 U / IECEx: PTB 05.0015U (Ex eb IIC Gb)
Rated voltage EN (Ex e II)550 V
Rated current (Ex e II)70 A
Rated current (Ex e II) with jumper67 A

Electrical data - Power Loss

Power loss, per pole (potential)2.426 W
Rated current I<sub>N</sub> for power loss specification76 A
Resistance value for specified, current-dependent power loss0 Ω

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Clamping units2
Total number of potentials1
Number of levels1
Number of jumper slots2

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section16 mm²
Solid conductor0.5 … 16 mm² / 20 … 6 AWG
Solid conductor; push-in termination6 … 16 mm² / 14 … 6 AWG
Fine-stranded conductor0.5 … 25 mm² / 20 … 4 AWG
Fine-stranded conductor; with insulated ferrule0.5 … 16 mm² / 20 … 6 AWG
Fine-stranded conductor; with ferrule; push-in termination6 … 16 mm² / 10 … 6 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. AWG specifications were converted according to IEC.
Strip length18 … 20 mm / 0.71 … 0.79 inches
Wiring directionFront-entry wiring

Physical data

Width12 mm / 0.472 inches
Height69.8 mm / 2.748 inches
Depth from upper-edge of DIN-rail36.9 mm / 1.453 inches
Depth43.5 mm / 1.713 inches

Mechanical data

Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colorred
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.382 MJ
Weight22.6 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

PU (SPU)20 pcs
Packaging typebox
Country of originDE
GTIN4055143786003
Customs tariff number85369010000

Product Classification

UNSPSC39121410
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 2016-1203”

Your email address will not be published. Required fields are marked *