Fast delivery within 72 Hours

Wago 2001-1506

Through terminal block, 2001 Series, Push-in CAGE CLAMP®Our through terminal block (item number 2001-1506) makes connecting wires quick and easy. Conductors should only be connected to this through te…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Through terminal block, 2001 Series, Push-in CAGE CLAMP®Our through terminal block (item number 2001-1506) makes connecting wires quick and easy. Conductors should only be connected to this through terminal block if their strip length is between 9 and 11 mm . Whether for industrial or building applications, you can use our through terminal blocks to connect electrical conductors quickly and safely. We offer variants for both classic through-wiring and potential distribution. Featuring conductor terminals along with Push-in CAGE CLAMP®, this product delivers reliable performance. Push-in CAGE CLAMP® technology provides a universal connection solution for all conductor types. It allows both solid and fine-stranded conductors with ferrules to be inserted directly into the clamping point without the need for tools. The dimensions are (4.2 x 80.6 x 39.5) mm (width x height x depth). This through terminal block is suitable for conductor cross sections ranging from 0.25 mm² to 2.5 mm².An operating tool is used to operate this through rail-mount terminal block. Our TOPJOB® S rail-mount terminal blocks are perfect for a wide range of industrial applications and modern building installations thanks to the secure electrical connections they provide. You can work anywhere in the world and on any application with just a single rail-mount terminal block system. This product is designed for specific Ex applications (please refer to the product datasheet).

Specification

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60947-7-1
Nominal voltage (III/3)800 V
Rated impulse withstand voltage (III / 3)8 kV
Rated current17.5 A
Current at conductor cross-section (max.) mm²24 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage800 V
Rated impulse withstand voltage8 kV
Rated current17.5 A
Current at conductor cross-section (max.) mm²24 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)600 V
Rated current UL (Use Group B)15 A
Rated voltage UL (Use Group C)600 V
Rated current UL (Use Group C)15 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current15 A / 15 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated voltage CSA (Use Group B)600 V
Rated current CSA (Use Group B)15 A
Rated voltage CSA (Use Group C)600 V
Rated current CSA (Use Group C)15 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current15 A / 15 A

Electrical data - Ex information

Reference to hazardous areasSee application instructions in section “Knowledge and Downloads – Documentation – Additional Information: Technical Section; Technical Explications”

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Clamping units5
Total number of potentials1
Number of levels1
Number of jumper slots2

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section1.5 mm²
Solid conductor0.25 … 2.5 mm² / 22 … 14 AWG
Solid conductor; push-in termination0.75 … 2.5 mm² / 18 … 14 AWG
Fine-stranded conductor0.25 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor; with insulated ferrule0.25 … 1.5 mm² / 22 … 16 AWG
Fine-stranded conductor; with ferrule; push-in termination0.75 … 1.5 mm² / 18 … 16 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length9 … 11 mm / 0.35 … 0.43 inches
Wiring directionFront-entry wiring

Physical data

Width4.2 mm / 0.165 inches
Height80.6 mm / 3.173 inches
Depth from upper-edge of DIN-rail32.9 mm / 1.295 inches
Depth39.5 mm / 1.555 inches

Mechanical data

Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Coloryellow
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.15 MJ
Weight7.1 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Commercial data

PU (SPU)20 pcs
Packaging typeBox
Country of originIN
GTIN4066966665178
Customs tariff number85369010000

Product Classification

UNSPSC39121410
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.