Specification

Model NameEnvironment-resistant temperature measurement unit
Model CodeNR-XTH08T
Series TitleMulti-input Data Logger
Series CodeNR-X series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117XT8T&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117XT8T
Manuals URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117XT8T
ModelNR-XTH08T
Input methodInsulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system)
Number of input channels8*1
Input connector typeMiniature thermocouple connector (Universal type)
Measurement cycleMaximum sampling cycle: 10 ms (100 Hz) to 1 h
A/D converting systemDelta-sigma method
A/D resolution24 bits
A/D integration time (noise filter)AUTO (Automatic configuration according to sampling cycle), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz)
Input typeThermocouple: K, J, E, T, R, S, B, N, C
Low pass filterPASS / 200 Hz / 20 Hz
AveragingSwitchable between ON/OFF, Averaging rate: 2 to 128 (moving average)
Reference contact compensationSwitchable between internal and external
Reference contact compensation accuracy±0.5°C ±0.9°F (23°C ±3°C 73.4°F ±5.4°F at input terminal temperature equilibrium)
Maximum input rating±30 V*2
Maximum allowable input ground voltageDry locations: 30 VAC and 42.4 Vpeak, or 60 VDCWet locations: 16 VAC and 22.6 Vpeak, or 35 VDC
Withstand voltageBetween measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minuteBetween measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute
Input impedance10 MΩ or more
Input signal source resistance2 kΩ or less
Thermocouple burnout detectionSwitchable between ON/OFF, When ON: Approx. 10 μA current detection*3
Measurable rangeK: −100 to +1372°C -148°F to +2501.6°F, −200 to −100°C -328°F to -148°FJ: −100 to +1200°C -148°F to +2192°F, −200 to −100°C -328°F to -148°FE: −100 to +1000°C -148°F to +1832°F, −200 to −100°C -328°F to -148°FT: −100 to +400°C -148°F to +752°F, −200 to −100°C -328°F to -148°FN: −100 to +1300°C -148°F to +2372°F, −200 to −100°C -328°F to -148°FC: 1500 to 2315°C 2732°F to 4199°F, 0 to 1500°C 32°F to 2732°FR: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°FS: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°FB: 400 to 600°C 752°F to 1112°F, 600 to 1820°C 1112°F to 3308°F
Measurement accuracyK: ±0.04% of rdg ±0.4°C ±0.7°F, ±0.43% of rdg ±0.1°C ±0.2°FJ: ±0.03% of rdg ±0.3°C ±0.5°F, ±0.30% of rdg ±0.1°C ±0.2°FE: ±0.03% of rdg ±0.3°C ±0.5°F, ±0.27% of rdg ±0.1°C ±0.2°FT: ±0.4°C ±0.7°F, ±0.34% of rdg ±0.1°C ±0.2°FN: ±0.02% of rdg ±0.6°C ±2.1°F, ±0.63% of rdg ±0.1°C ±0.2°FC: ±0.10% of rdg ±0.2°C ±0.4°F, ±0.04% of rdg ±0.8°C ±1.4°FR: ±0.01% of rdg ±1.2°C ±2.2°F, ±2.0°C ±3.6°FS: ±0.02% of rdg ±1.2°C ±2.2°F, ±2.0°C ±3.6°FB: ±2.2°C ±4.0°F, ±1.6°C ±2.9°F*4
Display resolutionK: 0.05°C 0.09°FJ: 0.05°C 0.09°FE: 0.05°C 0.09°FT: 0.01°C 0.02°FN: 0.05°C 0.09°FC: 0.05°C 0.09°FR: 0.05°C 0.09°FS: 0.05°C 0.09°FB: 0.05°C 0.09°F
Buffer memory16M data*5
Warm up time30 minutes or more
Common mode noise reduction ratio135 dB or more (up to 60 Hz DC) (typ.) *4
Remote connectionDedicated environment-resistant remote unit input port × 1 (Remote IN), output port × 1 (Remote OUT)Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cableConnectable to multiple environment-resistant measurement units*6
Synchronization accuracy between remote connection units±1 μs*7
Power supplySupplied from NR-X100W master unit
Power consumption5.0 W max.
Surrounding air temperature−40 to +85°C -40°F to +185°F*8
Operating ambient humidityMax. 100% RH*9
Vibration resistance100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*10Equivalent to JIS D1601 Stage 45 (Class 1, Class 2, and Class 3; equivalent to Class B) automotive vibration standard
Shock resistance1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27)
Enclosure ratingIP65/IP67 (IEC 60529)Enclosure Type 4X (UL 50E, CSA C22.2 No. 94.2, NEMA 250)Indoor/outdoor use
MaterialMain unit case: Aluminum die-casting (coated) / PBT+PC / PC, Display: Reinforced glass,Connectors: Brass (chromate processing), Connector protection cap: PBT+PC
WeightApprox. 660 g 23.30 oz