High-speed, high-voltage measurement unit. NR-HV04. Series: Multi-input Data Logger. Series code: NR-X series

Specification

Model NameHigh-speed, high-voltage measurement unit
Model CodeNR-HV04
Series TitleMulti-input Data Logger
Series CodeNR-X series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117HV04&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117HV04
Manuals URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117HV04
ModelNR-HV04 *1
TypeHigh-speed, high-voltage measurement unit
Input methodInsulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
Number of channels4 ch *2
Measurement cycleMaximum sampling cycle: 1 μs (1 MHz) to 60 s
A/D converting systemSuccessive approximation, simultaneous sampling of all channels
A/D resolution14 bit
Input frequency band250 kHz (−3 dB or more)
Input type±1000 V, ±500 V, ±200 V, ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
Low pass filterPASS, 7 Hz, 500 Hz, 50 kHz (−12 dB/oct)
Maximum input voltage[When using OP-89263 1:1 voltage-resistant probe] 1000 V peak and 700 Vrms, or 700 VDC;[When using OP-89264 1:1 voltage-resistant probe] 300 VDC + AC peak;[When using OP-88998 10:1 voltage-resistant probe] 1000 VDC + AC peak; [Direct input] 60 VDC + AC peak*3
Digital filterAveraging rate: 1 to 128 (automatically selected)
Withstand voltage2200 VAC (50/60 Hz) for 1 minute
Connector formatInsulated BNC connector
Input impedance1 MΩ ±1%, approx. 30 pF
Input couplingAC/DC/AC-RMS/DC-RMS
Measurable range±1000 V: −1000.00 to +1000.00 V±500 V: −550.00 to +550.00 V±200 V: −220.00 to +220.00 V±100 V: −110.000 to +110.000 V±50 V: −55.000 to +55.000 V±20 V: −22.000 to +22.000 V±10 V: −11.0000 to +11.0000 V±5 V: −5.5000 to +5.5000 V±2 V: −2.2000 to +2.2000 V
Measurement accuracy±0.1% of F.S., LPF: 500 Hz, with digital filter ON
Display resolution±1000 V: 50 mV±500 V: 20 mV±200 V: 10 mV±100 V: 5 mV±50 V: 2 mV±20 V: 1 mV±10 V: 0.5 mV±5 V: 0.2 mV±2 V: 0.1 mV
Buffer memory16M data*4
Warm up time30 minutes or more
RMS measurement function4 ch
Maximum allowable voltage to ground[When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II);[When using OP-89264 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II);[When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II);[Direct input] Measurement terminal, GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC*3
Residual noise level0.01% of F.S., LPF: 500 Hz (200 μs/S, digital filter: ON) (typ.); 0.05% of F.S., LPF: PASS (typ.)
CalculationfunctionCH1 to CH2, CH3 to CH4 (Single-channel usage not possible when using the calculation function)
Common mode noise reduction ratio80 dB or more (at max. 60 Hz DC) (typ.)
Rating3 W or less
Environmental resistance - Insulation resistance500 VDC, 10 MΩ or more
Environmental resistance - Ambient temperature0 to +40°C 32°F to 104°F
Environmental resistance - Relative humidity10 to 85% RH (no condensation)
WeightApprox. 270 g 9.53 oz