Specification
| Model Name | High-speed analog measurement unit |
|---|---|
| Model Code | NR-HA08 |
| Series Title | Multi-input Data Logger |
| Series Code | NR-X series |
| Data Sheet URL | https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117HA08&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US |
| CAD URL | https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117HA08 |
| Manuals URL | https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117HA08 |
| Model | NR-HA08 *1 |
| Type | High-speed analog measurement unit |
| Input method | Single-ended input / Balanced differential input selectionChannels not insulated from each other, input channels insulated from other units (PC) |
| Number of channels | Single-end: 8 ch*2 (Differential: 4 ch) / Current: 4 ch*3 |
| Measurement cycle | Maximum sampling cycle: 1 μs (1 MHz) to 60 s |
| A/D converting system | Successive approximation |
| A/D resolution | 14 bit |
| Input frequency band | 250 kHz (−3 dB typ.) |
| Input impedance - Voltage | 1 MΩ ±1% |
| Input impedance - Current | 250 Ω ±1% |
| Withstand voltage | 300 VAC (50/60 Hz), 1 minute |
| Input type - Voltage | ±10 V, ±5 V, ±2.5 V, ±1 V, ±0.5 V, ±0.25 V |
| Input type - Current | ±20 mA |
| Maximum input rating - Voltage range | ±30 V |
| Maximum input rating - Current range | ±30 mA |
| Measurable range | ±10 V: −11.000 to +11.000 V±5 V: −5.500 to +5.500 V±2.5 V: −2.7500 to +2.7500 V±1 V: −1.1000 to +1.1000 V±0.5 V: −550.0 to +550.0 mV±0.25 V: −275.00 to +275.00 mV±20 mA: −22.000 to +22.000 mA |
| Measurement accuracy - Zero-point accuracy | ±0.03% of F.S. |
| Measurement accuracy - DC amplitude accuracy | ±0.1% of F.S. (10 V/5 V/2.5 V/20 mA range at 16 averages, 1 V/0.5 V/0.25 V range at 128 averages) |
| Display resolution | ±10 V: 1 mV±5 V: 1 mV±2.5 V: 0.1 mV±1 V: 0.1 mV±0.5 V: 0.1 mV±0.25 V: 0.01 mV±20 mA: 1 μA |
| Buffer memory | 4M data*4 |
| Warm up time | 15 minutes or more |
| Rating | 3.3 W or less |
| Environmental resistance - Ambient temperature | 0 to +40°C 32°F to 104°F |
| Environmental resistance - Relative humidity | 10 to 85% RH (no condensation) |
| Weight | Approx. 150 g 5.30 oz |