Fast delivery within 72 Hours

Keyence NR-HA08

High-speed analog measurement unit. NR-HA08. Series: Multi-input Data Logger. Series code: NR-X series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

High-speed analog measurement unit. NR-HA08. Series: Multi-input Data Logger. Series code: NR-X series

Specification

Model Name

High-speed analog measurement unit

Model Code

NR-HA08

Series Title

Multi-input Data Logger

Series Code

NR-X series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117HA08&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117HA08

Manuals URL

https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117HA08

Model

NR-HA08 *1

Type

High-speed analog measurement unit

Input method

Single-ended input / Balanced differential input selectionChannels not insulated from each other, input channels insulated from other units (PC)

Number of channels

Single-end: 8 ch*2 (Differential: 4 ch) / Current: 4 ch*3

Measurement cycle

Maximum sampling cycle: 1 μs (1 MHz) to 60 s

A/D converting system

Successive approximation

A/D resolution

14 bit

Input frequency band

250 kHz (−3 dB typ.)

Input impedance - Voltage

1 MΩ ±1%

Input impedance - Current

250 Ω ±1%

Withstand voltage

300 VAC (50/60 Hz), 1 minute

Input type - Voltage

±10 V, ±5 V, ±2.5 V, ±1 V, ±0.5 V, ±0.25 V

Input type - Current

±20 mA

Maximum input rating - Voltage range

±30 V

Maximum input rating - Current range

±30 mA

Measurable range

±10 V: −11.000 to +11.000 V±5 V: −5.500 to +5.500 V±2.5 V: −2.7500 to +2.7500 V±1 V: −1.1000 to +1.1000 V±0.5 V: −550.0 to +550.0 mV±0.25 V: −275.00 to +275.00 mV±20 mA: −22.000 to +22.000 mA

Measurement accuracy - Zero-point accuracy

±0.03% of F.S.

Measurement accuracy - DC amplitude accuracy

±0.1% of F.S. (10 V/5 V/2.5 V/20 mA range at 16 averages, 1 V/0.5 V/0.25 V range at 128 averages)

Display resolution

±10 V: 1 mV±5 V: 1 mV±2.5 V: 0.1 mV±1 V: 0.1 mV±0.5 V: 0.1 mV±0.25 V: 0.01 mV±20 mA: 1 μA

Buffer memory

4M data*4

Warm up time

15 minutes or more

Rating

3.3 W or less

Environmental resistance - Ambient temperature

0 to +40°C 32°F to 104°F

Environmental resistance - Relative humidity

10 to 85% RH (no condensation)

Weight

Approx. 150 g 5.30 oz

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence NR-HA08”

Your email address will not be published. Required fields are marked *