Keyence NR-FV04

Pulse measurement unit. NR-FV04. Series: Multi-input Data Logger. Series code: NR-X series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Pulse measurement unit. NR-FV04. Series: Multi-input Data Logger. Series code: NR-X series

Specification

Model NamePulse measurement unit
Model CodeNR-FV04
Series TitleMulti-input Data Logger
Series CodeNR-X series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117FV04&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117FV04
Manuals URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117FV04
ModelNR-FV04 *1
TypePulse measurement unit
Input methodInsulated single-end input, channels insulated from each other, input channels insulated from other units (PC)
Number of channels4 ch *2
Measurement cycleMaximum sampling cycle: 1 μs (1 MHz) to 60 s
A/D converting systemSuccessive approximation, simultaneous sampling of all channels
A/D resolution14 bit
Input frequency band250 kHz (−3 dB or more)
Low pass filterPASS, 1.5 kHz, 15 kHz, 50 kHz
Pulse input - Input typePulse frequency, pulse count (Single-phase input)
Pulse input - Maximum input voltage±700 V *3
Pulse input - Threshold voltage+100 V, +50 V, +20 V, +10 V, +5 V, +2.5 V, +1 V, +500 mV, +250 mV, +100 mV, +50 mV, 0 V
Pulse input - Minimum pulse duration2 μs or more for both ON and OFF
Pulse input - HysteresisAUTO, 100 mV, 500 mV, 5 V
Pulse input - Pulse divisions1 to 64 (Can be set to units of 1 division)
Pulse input - Input couplingDC rising edge, DC falling edge, AC rising edge, AC falling edge
Pulse input - Digital filterPulse frequency: Averaging rate of 1 to 32768 (automatically selected), Pulse count: None
Pulse input - Predictive functionsPredictive calculation, Stop prediction (OFF, ×1.5, ×3, ×5, ×8, ×16)
Pulse input - Sensor power outputDedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003; +12 V, 50 mA or +5 V, 50 mANPN open-collector output connectable, sensor power supply not insulated from system bus
Voltage input - Input type±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V
Voltage input - Maximum input voltage±700 V *3
Voltage input - Digital filterAveraging rate: 1 to 128 (automatically selected)
Voltage input - Input couplingDC, AC
Voltage input - Common mode noise reduction ratio80 dB or more (at up to 60 Hz DC)
Voltage input - Residual noise level0.02% of F.S., LPF: 1.5 kHz (200 μs/S, digital filter: ON); 0.05% of F.S., LPF: PASS
Measurement range - Pulse frequencyMeasurable range: 0.05 to 16000.00 Hz, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency)
Measurement range - Pulse countMeasurable range: 0 to 65,000 counts/sampling cycle, Display resolution: 1 count
Measurement range - ±100 VMeasurable range: −110.000 to +110.000 V, Display resolution: 5 mV
Measurement range - ±50 VMeasurable range: −55.000 to +55.000 V, Display resolution: 2 mV
Measurement range - ±20 VMeasurable range: −22.000 to +22.000 V, Display resolution: 1 mV
Measurement range - ±10 VMeasurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV
Measurement range - ±5 VMeasurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV
Measurement range - ±2 VMeasurable range: −2.2000 to +2.2000 V, Display resolution: 0.1 mV
Measurement accuracy - Pulse frequency±0.07% of rdg, ±0.01 Hz (20 Hz to 15 kHz, 20 ms/S, with digital filter ON)
Measurement accuracy - Voltage input±0.1% of F.S., LPF: 500 Hz, with digital filter ON
Withstand voltage2200 VAC (50/60 Hz) for 1 minute
Connector formatInsulated BNC connector
Input impedance1 MΩ ±1%, approx. 30 pF
Buffer memory16M data*4
Warm up time30 minutes or more
Maximum allowable voltage to ground[When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II);[When using OP-89264 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II);[When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II);[Direct input] Measurement terminal, GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC*3
Rating4 W or less (including OP-88003 sensor power supply)
Environmental resistance - Insulation resistance500 VDC, 10 MΩ or more
Environmental resistance - Ambient temperature0 to +40°C 32°F to 104°F
Environmental resistance - Relative humidity10 to 85% RH (no condensation)
WeightApprox. 270 g 9.53 oz