Fast delivery within 72 Hours
Keyence LR-XN11C
Separate Amplifier Model, Amplifier Units Main unit (M8 Connector Type). LR-XN11C. Series: Compact Laser Sensor. Series code: LR-X series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Separate Amplifier Model, Amplifier Units Main unit (M8 Connector Type). LR-XN11C. Series: Compact Laser Sensor. Series code: LR-X series
Specification
| Model Name | Separate Amplifier Model, Amplifier Units Main unit (M8 Connector Type) |
|---|---|
| Model Code | LR-XN11C |
| Series Title | Compact Laser Sensor |
| Series Code | LR-X series |
| Data Sheet URL | https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57360&dlModelId=PM_24XN11C&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US |
| CAD URL | https://www.keyence.com/products/sensor/photoelectric/lr-x/downloads/?mode=cd&modelId=PM_24XN11C |
| Manuals URL | https://www.keyence.com/products/sensor/photoelectric/lr-x/downloads/?mode=ma&modelId=PM_24XN11C |
| Model | LR-XN11C |
| Type | NPN Output/PNP Output (Selectable output) |
| Cable/Connector | M8 connector*1 |
| Main Unit/Expansion Unit | Main Unit (expansion not possible) |
| No. of Control Outputs | 2*2 |
| No. of External Inputs | 1*2 |
| Response Time | 500 µs*3/1 ms/3 ms/10 ms/200 ms Selectable |
| IO-Link | Specification v1.1/COM2 (38.4 kbps) |
| Functions | Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
| I/O - Control Output | Open collector, 30 VDC or lower, N.O./N.C.100 mA or lower for 1 output; 100 mA or lower in total for 2 outputsResidual voltage NPN: 1.4 V or lower (output current: 10 mA or lower)/2 V or lower (output current: 10 to 100 mA), PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA) |
| I/O - External Input | External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectableShort circuit current – NPN: 1 mA or lower, PNP: 2 mA or lowerInput time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected) |
| Unit Expansion | — |
| Protection Circuit | Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection |
| Number of Interference Prevention Devices | — |
| Power supply - Power voltage | 16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2 |
| Power supply - Power consumption | During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current) |
| Environmental resistance - Ambient temperature | −20 to +55°C -4°F to 131°F (no freezing)*5 |
| Environmental resistance - Relative humidity | 35 to 85% RH (no condensation) |
| Environmental resistance - Vibration resistance | 10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions |
| Environmental resistance - Shock resistance | 500 m/s2 (50G); 3 times each for X, Y, and Z axes |
| Case Material | Main Unit and Cover: Polycarbonate |
| Accessories | Instruction manual |
| Weight | Approx. 22 g |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Keyence LR-XN11C” Cancel reply

Reviews
Clear filtersThere are no reviews yet.