Fast delivery within 72 Hours

Keyence KV-CA02

Camera input unit. KV-CA02. Series: Programmable Logic Controller. Series code: KV-X series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Camera input unit. KV-CA02. Series: Programmable Logic Controller. Series code: KV-X series

Specification

Model NameCamera input unit
Model CodeKV-CA02
Series TitleProgrammable Logic Controller
Series CodeKV-X series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157158&dlModelId=PM_084CA02&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/controls/plc-building-block-type/kv-x/downloads/?mode=cd&modelId=PM_084CA02
Manuals URLhttps://www.keyence.com/products/controls/plc-building-block-type/kv-x/downloads/?mode=ma&modelId=PM_084CA02
ModelKV-CA02 *1
General specifications - Power voltageSystem configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)*2System configuration using an expansion unit only for KV-8000/7000 Series: 24 VDC (-15%/+20%)*2
General specifications - Operating ambient temperatureSystem configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F(no freezing)*3*4System configuration using an expansion unit only for KV-8000/7000 Series: 0 to +55°C 32 to 131°F(no freezing)*3*4
General specifications - Operating ambient humiditySystem configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH(no condensation)*3System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH(no condensation)*3
General specifications - Storage ambient temperatureSystem configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F*3System configuration using an expansion unit only for KV-8000/7000 Series: -25 to +75°C -13 to +167°F*3
General specifications - Storage relative humiditySystem configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH(no condensation)*3System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH(no condensation)*3
General specifications - Operating environmentNo dust or corrosive gas
General specifications - Operating altitude2000 m 6561.7′ or less
General specifications - Noise immunity1500 Vp-p or morePulse duration: 1 μs, 50 ns (based on noise simulator)IEC standard-compliant (IEC 61000-4-2/3/4/6)
General specifications - Withstand voltage1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case)
General specifications - Insulation resistance50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter)
General specifications - Vibration resistanceHalf amplitude 3.5 mm 0.14″*5
General specificationsAcceleration 9.8 m/s2 32.2’/s2*5
General specifications - Shock resistanceAcceleration: 150 m/s2 492.1’/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions
General specifications - Pollution degree2
Performance specifications - Connectable CPU unitKV-X Series/KV-8000A
Performance specifications - Max. number of connectable units4
Performance specifications - Number of ports2
Performance specifications - Supported camera modelsKV-CA1H (Compact standard camera)KV-CA1W (Wide-field high-resolution camera)
Performance specifications - Cable length5/10/20 m 16.4’/32.8’/65.6’*6
Performance specifications - Recording timeApprox. 3 minutes*7
Performance specifications - Internal current consumption260 mA or less*8
Performance specifications - WeightApprox. 190 g