Fast delivery within 72 Hours

Keyence KV-CA02

Camera input unit. KV-CA02. Series: Programmable Logic Controller. Series code: KV-X series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Camera input unit. KV-CA02. Series: Programmable Logic Controller. Series code: KV-X series

Specification

Model Name

Camera input unit

Model Code

KV-CA02

Series Title

Programmable Logic Controller

Series Code

KV-X series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157158&dlModelId=PM_084CA02&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/controls/plc-building-block-type/kv-x/downloads/?mode=cd&modelId=PM_084CA02

Manuals URL

https://www.keyence.com/products/controls/plc-building-block-type/kv-x/downloads/?mode=ma&modelId=PM_084CA02

Model

KV-CA02 *1

General specifications - Power voltage

System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)*2System configuration using an expansion unit only for KV-8000/7000 Series: 24 VDC (-15%/+20%)*2

General specifications - Operating ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F(no freezing)*3*4System configuration using an expansion unit only for KV-8000/7000 Series: 0 to +55°C 32 to 131°F(no freezing)*3*4

General specifications - Operating ambient humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH(no condensation)*3System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH(no condensation)*3

General specifications - Storage ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F*3System configuration using an expansion unit only for KV-8000/7000 Series: -25 to +75°C -13 to +167°F*3

General specifications - Storage relative humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH(no condensation)*3System configuration using an expansion unit only for KV-8000/7000 Series: 5 to 95% RH(no condensation)*3

General specifications - Operating environment

No dust or corrosive gas

General specifications - Operating altitude

2000 m 6561.7' or less

General specifications - Noise immunity

1500 Vp-p or morePulse duration: 1 μs, 50 ns (based on noise simulator)IEC standard-compliant (IEC 61000-4-2/3/4/6)

General specifications - Withstand voltage

1500 VAC for one minute (between the power terminals and the I/O terminals, and between the external terminals and the case)

General specifications - Insulation resistance

50 MΩ or more (between the power terminals and the I/O terminals and between the external terminals and the case, with 500 VDC megohmmeter)

General specifications - Vibration resistance

Half amplitude 3.5 mm 0.14"*5

General specifications

Acceleration 9.8 m/s2 32.2'/s2*5

General specifications - Shock resistance

Acceleration: 150 m/s2 492.1'/s2, Application time: 11 ms, 2 times in each of the X, Y, and Z directions

General specifications - Pollution degree

2

Performance specifications - Connectable CPU unit

KV-X Series/KV-8000A

Performance specifications - Max. number of connectable units

4

Performance specifications - Number of ports

2

Performance specifications - Supported camera models

KV-CA1H (Compact standard camera)KV-CA1W (Wide-field high-resolution camera)

Performance specifications - Cable length

5/10/20 m 16.4'/32.8'/65.6'*6

Performance specifications - Recording time

Approx. 3 minutes*7

Performance specifications - Internal current consumption

260 mA or less*8

Performance specifications - Weight

Approx. 190 g

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence KV-CA02”

Your email address will not be published. Required fields are marked *