Programmable Logic Controller. KV-8000A. Series: Programmable Logic Controller. Series code: KV-8000 series

Specification

Model NameProgrammable Logic Controller
Model CodeKV-8000A
Series TitleProgrammable Logic Controller
Series CodeKV-8000 series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57344&dlModelId=PM_084800A&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/controls/plc-building-block-type/kv-8000/downloads/?mode=cd&modelId=PM_084800A
Manuals URLhttps://www.keyence.com/products/controls/plc-building-block-type/kv-8000/downloads/?mode=ma&modelId=PM_084800A
ModelKV-8000A
General specifications - Power voltageSystem configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)System configuration using an expansion unit for KV-8000/7000 Series only: 24 VDC (-15%/+20%)
General specifications - Operating ambient temperatureSystem configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F (No freezing)System configuration using an expansion unit for KV-8000/7000 Series only: 0 to +55°C 32 to 131°F (No freezing)
General specifications - Operating ambient humiditySystem configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH (No condensation)System configuration using an expansion unit for KV-8000/7000 Series only: 5 to 95% RH (No condensation)
General specifications - Storage ambient temperatureSystem configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°FSystem configuration using an expansion unit for KV-8000/7000 Series only: -25 to +75°C -13 to +167°F
General specifications - Storage relative humiditySystem configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH (No condensation)System configuration using an expansion unit for KV-8000/7000 Series only: 5 to 95% RH (No condensation)
General specifications - Operating environmentNo dust or corrosive gas
General specifications - Operating altitude2000 m 6561.7′ or less
General specifications - Noise immunity1500 Vp-p or morePulse width: 1 μs, 50 ns (based on a noise simulator)IEC standard-compliant (IEC61000-4-2/3/4/6)
General specifications - Withstand voltage1500 VAC, 1 minute (between the power supply terminal and the I/O terminals and between the external terminals and the case)
General specifications - Insulation resistance50 MΩ or more (between the power terminals and the I/O terminals, and between the external terminals and the case, with 500 VDC megohmmeter)
General specifications - Vibration resistanceHalf amplitude 3.5 mm 0.14″*1
General specificationsAcceleration 9.8 m/s2 32.2’/s2*1
General specifications - Internal current consumption400 mA or less*2
General specifications - Shock resistanceAcceleration 150 m/s2 492.1’/s2, Operation time 11 ms, twice in each of the X, Y and Z directions
General specifications - Overvoltage categoryI (II when using KV-PU1)
General specifications - Pollution degree2
General specifications - WeightKV-8000A: Approx. 340 gKV-B1 (battery): Approx. 10 g
Performance specifications - Arithmetic control modeStored program mode
Performance specifications - I/O control modeRefresh mode
Performance specifications - Program languageExpanded ladder, KV Script, mnemonic
Performance specifications - Number of commandsBasic instructions: 80 classes, 181 instructionsApplied instructions: 55 classes, 73 instructionsArithmetic operation instruction: 128 classes, 327 instructionsExtended instructions: 78 classes, 133 instructionsTotal: 341 classes, 714 instructions
Performance specifications - Instruction execution speedBasic instructions: Min. 0.96 nsApplied instructions: Min. 5.75 nsDouble precision floating-point instruction: Min. 58 ns
Performance specifications - CPU memory capacity64 MB
Performance specifications - Program capacityApprox. 1500 k steps
Performance specifications - Maximum number of units to be installed16 units (KV-8000/7000 Series expansion unit only)48 units (KV-8000/7000 Series expansion unit, KV-5000/3000 Seriesexpansion unit (when extension unit (KV-EB1) is used))
Performance specifications - Maximum number of I/O pointsMaximum 3072 points for expansion(KV-EB1S/KV-EB1R: 2 units used, 64-point unit used)
Performance specifications - Bit deviceTotal 32000 points 1 bit
Performance specifications - Self-diagnosis functionCPU error, RAM error, other
Performance specifications64000 points 1 bit
Performance specifications - Word device4000 points 32 bits
Performance specifications - Number of comments/ labels stored in main unitApprox. 224000
Performance specifications - Power failure hold functionFlash ROM can be written 10000 times