Fast delivery within 72 Hours

Keyence KV-8000A

Programmable Logic Controller. KV-8000A. Series: Programmable Logic Controller. Series code: KV-8000 series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Programmable Logic Controller. KV-8000A. Series: Programmable Logic Controller. Series code: KV-8000 series

Specification

Model Name

Programmable Logic Controller

Model Code

KV-8000A

Series Title

Programmable Logic Controller

Series Code

KV-8000 series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57344&dlModelId=PM_084800A&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/controls/plc-building-block-type/kv-8000/downloads/?mode=cd&modelId=PM_084800A

Manuals URL

https://www.keyence.com/products/controls/plc-building-block-type/kv-8000/downloads/?mode=ma&modelId=PM_084800A

Model

KV-8000A

General specifications - Power voltage

System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%)System configuration using an expansion unit for KV-8000/7000 Series only: 24 VDC (-15%/+20%)

General specifications - Operating ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F (No freezing)System configuration using an expansion unit for KV-8000/7000 Series only: 0 to +55°C 32 to 131°F (No freezing)

General specifications - Operating ambient humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH (No condensation)System configuration using an expansion unit for KV-8000/7000 Series only: 5 to 95% RH (No condensation)

General specifications - Storage ambient temperature

System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°FSystem configuration using an expansion unit for KV-8000/7000 Series only: -25 to +75°C -13 to +167°F

General specifications - Storage relative humidity

System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH (No condensation)System configuration using an expansion unit for KV-8000/7000 Series only: 5 to 95% RH (No condensation)

General specifications - Operating environment

No dust or corrosive gas

General specifications - Operating altitude

2000 m 6561.7' or less

General specifications - Noise immunity

1500 Vp-p or morePulse width: 1 μs, 50 ns (based on a noise simulator)IEC standard-compliant (IEC61000-4-2/3/4/6)

General specifications - Withstand voltage

1500 VAC, 1 minute (between the power supply terminal and the I/O terminals and between the external terminals and the case)

General specifications - Insulation resistance

50 MΩ or more (between the power terminals and the I/O terminals, and between the external terminals and the case, with 500 VDC megohmmeter)

General specifications - Vibration resistance

Half amplitude 3.5 mm 0.14"*1

General specifications

Acceleration 9.8 m/s2 32.2'/s2*1

General specifications - Internal current consumption

400 mA or less*2

General specifications - Shock resistance

Acceleration 150 m/s2 492.1'/s2, Operation time 11 ms, twice in each of the X, Y and Z directions

General specifications - Overvoltage category

I (II when using KV-PU1)

General specifications - Pollution degree

2

General specifications - Weight

KV-8000A: Approx. 340 gKV-B1 (battery): Approx. 10 g

Performance specifications - Arithmetic control mode

Stored program mode

Performance specifications - I/O control mode

Refresh mode

Performance specifications - Program language

Expanded ladder, KV Script, mnemonic

Performance specifications - Number of commands

Basic instructions: 80 classes, 181 instructionsApplied instructions: 55 classes, 73 instructionsArithmetic operation instruction: 128 classes, 327 instructionsExtended instructions: 78 classes, 133 instructionsTotal: 341 classes, 714 instructions

Performance specifications - Instruction execution speed

Basic instructions: Min. 0.96 nsApplied instructions: Min. 5.75 nsDouble precision floating-point instruction: Min. 58 ns

Performance specifications - CPU memory capacity

64 MB

Performance specifications - Program capacity

Approx. 1500 k steps

Performance specifications - Maximum number of units to be installed

16 units (KV-8000/7000 Series expansion unit only)48 units (KV-8000/7000 Series expansion unit, KV-5000/3000 Seriesexpansion unit (when extension unit (KV-EB1) is used))

Performance specifications - Maximum number of I/O points

Maximum 3072 points for expansion(KV-EB1S/KV-EB1R: 2 units used, 64-point unit used)

Performance specifications - Bit device

Total 32000 points 1 bit

Performance specifications - Self-diagnosis function

CPU error, RAM error, other

Performance specifications

64000 points 1 bit

Performance specifications - Word device

4000 points 32 bits

Performance specifications - Number of comments/ labels stored in main unit

Approx. 224000

Performance specifications - Power failure hold function

Flash ROM can be written 10000 times

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence KV-8000A”

Your email address will not be published. Required fields are marked *