Fast delivery within 72 Hours
Keyence GL-T11R
Safety Relay Terminal. GL-T11R. Series: Safety Light Curtain. Series code: GL-R series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Safety Relay Terminal. GL-T11R. Series: Safety Light Curtain. Series code: GL-R series
Specification
| Model Name | Safety Relay Terminal |
|---|---|
| Model Code | GL-T11R |
| Series Title | Safety Light Curtain |
| Series Code | GL-R series |
| Data Sheet URL | https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR54488&dlModelId=PM_247T11R&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US |
| CAD URL | https://www.keyence.com/products/safety/light-curtain/gl-r/downloads/?mode=cd&modelId=PM_247T11R |
| Manuals URL | https://www.keyence.com/products/safety/light-curtain/gl-r/downloads/?mode=ma&modelId=PM_247T11R |
| Model | GL-T11R |
| Applicable model | GL-R Series |
| Relay output | 250 VAC 6 A 30 VDC 6 A (Resistance load)240 VAC 2 A (COSø=0.3) (Inductive load)24 VDC 1 A (COSø=0.3) (Inductive load) |
| Life-span | 100,000 cycles or more with 250 VAC 6 A resistance load (open/close frequency: 20 times/minute)100,000 cycles or more with 30 VDC 6 A resistance load (open/close frequency: 20 times/minute)500,000 cycles or more with 250 VAC 1 A resistance load (open/close frequency: 30 times/minute)500,000 cycles or more with 30 VDC 1 A resistance load (open/close frequency: 30 times/minute)AC15: 100,000 cycles or more with 240 VAC 2 A inductive load (open/close frequency: 20 times/minute, cosø = 0.3)DC13: 100,000 cycles or more with 24 VDC 1 A inductive load (open/close frequency: 20 times/minute, L/R = 48 ms) |
| Response time - ON→OFF | GL-R +10 ms |
| Response time - OFF→ON | GL-R +32 ms |
| Supplemental output (Non-safety-related output) - AUX | Transistor output (PNP/NPN input device can be connected.)*150 mA max., residual voltage 2.5 V max. (When the cable between the GL-R and GL-T11R is 5 m) |
| Supplemental output (Non-safety-related output) - Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W)LED lamp (load current: 10 to 230 mA) can be connected. |
| External input | ON voltage: [Power supply voltage – 5 V] to [Power supply voltage]OFF voltage: Open or 0 to 3 VShort circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
| Power supply - Power voltage | 24 VDC ±10%, ripple (P-P) 10% or less, Class 2 |
| Power supply - Current consumption. | 100 mA max. (24 VDC, GL-T11R only) |
| Approved standards - EMC | EN61496-1, UL61496-1, IEC61496-1 |
| Approved standards | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
| Approved standards - Safety | EN61496-1, UL61496-1, IEC61496-1 (Type4 ESPE)EN ISO13849-1 : 2015 (Category4, PLe)UL508, EN50178 |
| Environmental resistance - Enclosure rating | IP20 (IEC60529)Must be installed within a control panel rated at IP54 or higher. |
| Environmental resistance - Pollution degree | 2 |
| Environmental resistance - Overvoltage category | III |
| Environmental resistance - Operating ambient temperature | -10 to +55 °C 14 to 131 °F (No freezing) |
| Environmental resistance - Operating relative humidity | 15 to 85 % RH (No condensation) |
| Environmental resistance - Storage temperature | -25 to +60 °C -13 to 140 °F (No freezing) |
| Environmental resistance - Storage relative humidity | 15 to 95 % RH |
| Environmental resistance - Altitude | 2,000 m or less |
| Environmental resistance - Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm 0.03″, 20 sweeps in each of the X, Y, and Z directions |
| Environmental resistance - Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
| Material | Polycarbonate |
| Weight | Approx. 310 g |