Fast delivery within 72 Hours

Keyence FR-LEX20

Long-range sensor main unit 2-wire explosion-proof model. FR-LEX20. Series: Radar Level Sensor. Series code: FR series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Long-range sensor main unit 2-wire explosion-proof model. FR-LEX20. Series: Radar Level Sensor. Series code: FR series

Specification

Model NameLong-range sensor main unit 2-wire explosion-proof model
Model CodeFR-LEX20
Series TitleRadar Level Sensor
Series CodeFR series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157159&dlModelId=PM_28LEX20&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/level/fr/downloads/?mode=cd&modelId=PM_28LEX20
Manuals URLhttps://www.keyence.com/products/process/level/fr/downloads/?mode=ma&modelId=PM_28LEX20
ModelFR-LEX20
Type2-wire explosion-proof model
Measuring rangeUp to 20 m 65.6’*1
Display rangeUp to 25 m 82.0’*1
Measurable dielectric constant of medium2 or more *2
Resolution1 mm 0.04″
PrecisionUp to 0.1 m 0.3′: ±10 mm 0.39″;0.1 to 10 m 0.3′ to 32.8′ : ±1 mm 0.04″;10 to 20 m 32.8′ to 65.6′: ±2 mm 0.08″*3
Response time1 s, 4 s (default value), 10 s, 25 s
Tank pressure-0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F)
Material - Tank interiorLens: PTFE;Internal seal: FFKM;Fastener: SUS304
Material - HousingPPS PC PA Internal potting agent: Epoxy resin(when using an Isolated barrier) Barrier: PC(when using a Zener barrier) Barrier: PC(when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: Aluminium die casting, NBRCable glands: Nickel-plated brass, chloroprene
Connection diameterG1-1/2 (40A)
Output - No. of control outputs
Output - Analog output4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response])
Network compatibilityHART
Analog output accuracy - Resolution1 mm 0.04″*4
Analog output accuracy - Zero accuracy±0.1 mA (zero point = 4 mA) *4
Analog output accuracy - F.S. accuracy±0.2 mA (full scale = 20 mA) *4
Power supply - Power voltage18.3 to 35 VDC.(when using an Isolated barrier) 24 VDC +25%/-10%(when using a Zener barrier) 20.1 to 28 VDC(when using a Zener barrier with a flameproof enclosure) 20.1 to 28 VDC
Power supply - Power consumption752.5 mW or less (including analog output; excluding load current)(when using an Isolated barrier) 3 W or less(when using a Zener barrier) 602 mW or less(when using a Zener barrier with a flameproof enclosure) 602 mW or less
Environmental resistance - Ambient temperature-30 to +60°C -22 to 140°F (no freezing)(when using an Isolated barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing)(when using a Zener barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing)(when using a Zener barrier with a flameproof enclosure) Barrier: -30 to +60°C -22 to 140°F(no freezing)
Environmental resistance - Relative humidityUp to 85% RH (no condensation)
Environmental resistance - Temperature of coupling used-30 to +85°C -22 to 185°F (no freezing)
Environmental resistance - Vibration resistance10 to 500 Hz; Power spectral density: 0.816 G2 X, Y and Z directions
Environmental resistance - Shock resistance100 m/s2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions
IECEx - Explosion-proof performanceEx ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da(when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC(when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC(when using a Zener barrier with a flameproof enclosure) Ex db [ia Ga] IIB T4 Gb Ex tb [ia Da] IIIC T135°C Db
IECEx - ZoneZone 0/20(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier with a flameproof enclosure) Zone 1/21
IECEx - Electrical ratingsUi: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / Lo (IIB): 0.2 mH / Co (IIB): 0.72 μF(when using a Zener barrier) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF(when using a Zener barrier with a flameproof enclosure) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF
IECEx - Temperature-30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F
ATEX and UKEX - Explosion-proof performanceII 1 G Ex ia IIC T4 Ga or II 1 G Ex ia IIB T4 Ga II 1 D Ex ia IIIC T135°C Da(when using an Isolated barrier) II (1) G [Ex ia Ga] IIC or II (1) G [Ex ia Ga] IIB II (1) D [Ex ia Da] IIIC(when using a Zener barrier) II (1) G [Ex ia Ga] IIB II (1) D [Ex ia Da] IIIC(when using a Zener barrier with a flameproof enclosure) II 2 (1) G Ex db [ia Ga] IIB T4 Gb II 2 (1) D Ex tb [ia Da] IIIC T135°C Db
ATEX and UKEX - ZoneZone 0/20(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier with a flameproof enclosure) Zone 1/21
ATEX and UKEX - Electrical ratingsUi: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / Lo (IIB): 0.2 mH / Co (IIB): 0.72 μF(when using a Zener barrier) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF(when using a Zener barrier with a flameproof enclosure) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF
ATEX and UKEX - Temperature-30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F
Type Approval of Electrical Equipment for Use in Explosive Atmospheres - Explosion-proof performanceEx ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da(when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC(when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC(when using a Zener barrier with a flameproof enclosure) Ex db [ia Ga] IIB T4 Gb Ex tb [ia Da] IIIC T135°C Db
Type Approval of Electrical Equipment for Use in Explosive Atmospheres - ZoneZone 0/20(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier with a flameproof enclosure) Zone 1/21
Type Approval of Electrical Equipment for Use in Explosive Atmospheres - Electrical ratingsUi: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / Lo (IIB): 0.2 mH / Co (IIB): 0.72 μF(when using a Zener barrier) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF(when using a Zener barrier with a flameproof enclosure) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF
Type Approval of Electrical Equipment for Use in Explosive Atmospheres - Temperature-30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F
NRTL/ACO - Explosion-proof performanceClass I, Zone 0, AEx ia IIC T4 Ga/Zone 20, AEx ia IIIC T135°C Da/Class I, Division 1, Groups A, B, C, D, T4/Class II, Division 1, Groups E, F, G, T135°C/Class III, Division 1 or Class I, Zone 0, AEx ia IIB T4 Ga/Zone 20, AEx ia IIIC T135°C Da/Class I, Division 1, Groups C, D, T4/Class II, Division 1, Groups E, F, G, T135°C /Class III, Division 1(when using an Isolated barrier) [AEx ia Ga] IIC or [AEx ia Ga] IIB/[AEx ia Da] IIIC Intrinsically safe circuit for Class I, Division 1, Groups A, B, C, D or Class I, Division 1, Groups C, D/Class II, Division 1, Groups E, F, G/Class III, Division 1(when using a Zener barrier) [AEx ia Ga] IIB/[AEx ia Da] IIIC Intrinsically safe circuit for Class I, Division 1, Groups C, D/Class II, Division 1, Groups E, F, G/Class III, Division 1(when using a Zener barrier with a flameproof enclosure) Class I, Zone 1, AEx db [ia Ga] IIB T4 Gb/Zone 21, AEx tb [ia Da] IIIC T135°C Db/Class I, Division 1, Groups C, D, T4/Class II, Division 1, Groups E, F, G, T135°C /Class III, Division 1
NRTL/ACO - Zone/DivisionZone 0/20 Division 1(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier with a flameproof enclosure) Zone 1/21 Division 1
NRTL/ACO - Electrical ratingsUi: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / Lo (IIB): 0.2 mH / Co (IIB): 0.72 μF(when using a Zener barrier) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF(when using a Zener barrier with a flameproof enclosure) Um: 250 VRMS / Uo: 34.33 VDC / Io: 112.007 mA / Po: 961.3 mW / Lo: 1.0 mH / Co: 0.37 μF
NRTL/ACO - Temperature-30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F
Enclosure ratingIP67 (IEC60529), Enclosure Type 4X (NEMA250)(when using an Isolated barrier) Barrier: Not specified(when using a Zener barrier) Barrier: Not specified(when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure : IP67 (IEC60529) Enclosure Type 4X (NEMA250)
Protection circuitReverse power connection protection, power supply surge protection
WeightApprox. 920 g 32.45 oz(when using an Isolated barrier) Barrier: Approx. 320 g 11.28 oz(when using a Zener barrier) Barrier: Approx. 100 g 3.52 oz(when using a Zener barrier with a flameproof enclosure) Flameproof enclosure + barrier (without cable glands): Approx. 1300 g 45.85 oz

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence FR-LEX20”

Your email address will not be published. Required fields are marked *