Fast delivery within 72 Hours
Keyence FD-R80
Sensor Main Unit 65A/80A Type. FD-R80. Series: Clamp-on Flow Meter. Series code: FD-R series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Sensor Main Unit 65A/80A Type. FD-R80. Series: Clamp-on Flow Meter. Series code: FD-R series
Specification
| Model Name | Sensor Main Unit 65A/80A Type |
|---|---|
| Model Code | FD-R80 |
| Series Title | Clamp-on Flow Meter |
| Series Code | FD-R series |
| Data Sheet URL | https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57328&dlModelId=PM_160R80&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US |
| CAD URL | https://www.keyence.com/products/process/flow/fd-r/downloads/?mode=cd&modelId=PM_160R80 |
| Manuals URL | https://www.keyence.com/products/process/flow/fd-r/downloads/?mode=ma&modelId=PM_160R80 |
| Model | FD-R80 |
| Supported pipe diameter | 2 1/2″ (65 A), ø64 to ø83 2.52″ to 3.27″3″ (80 A), ø83 to ø100 3.27″ to 3.94″ |
| Supported pipe materials | Metal / resin*1 |
| Supported fluids | Various liquids (i.e. water, oils, chemicals)*1 |
| Supported fluid temperature | – 20 to + 120°C – 4.0 to + 248 °F (no freezing on the pipe surface)*2 |
| Maximum rated flow | Rated flow velocity range: 5.0 m/sFlow rate range (Typical):2 1/2″ (65 A): 1000 L/min 260 gal/min 60 m3/ h)3″ (80 A): 1500 L/min 390 gal/min 90 m3 / h |
| Zero cut flow rate | Zero cut: 0.3 m/s (default)*3Flow rate (Typical): 90 L / min 24 gal / min 5.4 m3/h |
| Display method | Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator |
| Display update cycle | Approx. 3 Hz |
| Display resolution | 1 (L / min) |
| Response time | 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable) |
| Measurement accuracy | Between 20 and 100% of F.S. : ±2.0% of RD*4*5Between 6 and 20% of F.S. : ±0.4% of F.S. *4*5 |
| Protection circuit | Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output |
| Zero point error | ±0.5% of F.S.*4*6 |
| Hysteresis | Variable |
| Flow units | L / min, m3 / h, gal / min |
| Integrated flow unit display | 1 / 10 / 100 / 1000 / 10000 (L) |
| Pipe temperature measurement accuracy | ±3°C ±5.4°F (liquid temperature of – 20 to + 50°C, – 4 to + 122°F)±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F)(ambient operating temperature of 25°C 77°F)*4 |
| Wiring specifications - Power supply | DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable) |
| Wiring specifications - I/O | When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block |
| Input/Output (Selectable) - Output (ch.1/ch.2) | Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7 |
| Input/Output (Selectable) - Analog output (ch.1/ch.2) | Flow rate analog output / Temperature analog output and 4 – 20 mA / 0 – 20 mA (selectable), load resistance: 500 Ω or less*7 |
| Input/Output (Selectable) - External input (ch.2) | Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7 |
| Rating - Power voltage | 20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC – 15% or + 10% (50 / 60 Hz) |
| Rating - Current consumption | When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less |
| Environmental resistance - Enclosure rating | IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250) |
| Environmental resistance - Ambient temperature | – 20 to + 60°C – 4.0 to 140 °F (no freezing)*2 |
| Environmental resistance - Relative humidity | 5 to 90%RH (no condensation) |
| Environmental resistance - Vibration resistance | 10 to 55 Hz, compound amplitude 1.5 mm 0.06″, XYZ axes 2 hours for each axis |
| Environmental resistance - Shock resistance | 100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis |
| Dimensions | Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60″ × 2.63″ × 2.78″ |
| Material - Main unit | Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent |
| Material - Unit rear | Rubber |
| Material - Upper/lower bracket | SUS304 |
| Weight | Main unit: Approx. 1.0 kgUpper/lower bracket: Approx.2.0 kg (including sub unit) |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Keyence FD-R80” Cancel reply

Reviews
Clear filtersThere are no reviews yet.