Fast delivery within 72 Hours

Keyence FD-H10K

Flow Sensors High-temperature model 8A/10A. FD-H10K. Series: Clamp-On Flow Sensor. Series code: FD-H series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Flow Sensors High-temperature model 8A/10A. FD-H10K. Series: Clamp-On Flow Sensor. Series code: FD-H series

Specification

Model NameFlow Sensors High-temperature model 8A/10A
Model CodeFD-H10K
Series TitleClamp-On Flow Sensor
Series CodeFD-H series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157135&dlModelId=PM_160H10K&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/fd-h/downloads/?mode=cd&modelId=PM_160H10K
Manuals URLhttps://www.keyence.com/products/process/flow/fd-h/downloads/?mode=ma&modelId=PM_160H10K
ModelFD-H10K
TypeHigh-temperature model
Supported pipe diameter1/4″ (8A), ø13–16 ø0.51″-0.63″3/8″ (10A), ø16–18 ø0.63″-0.71″
Supported pipe materialsMetal piping, hard plastic piping*1
Supported fluidsAll fluids (water, oil, chemicals, etc.)*1
Supported fluid temperature0–180°C 32–356°F (no freezing on pipe surface)*2*3
Maximum rated flow1/4″ (8A) : 20 L/min5.3 gal/min3/8″ (10A) : 30 L/min7.9 gal/min
Zero cut flow rate0.3 L/min 0.08 gal/min (variable, initial value)
Detection principleDelta TOF + Pulse Doppler
Function for automatic correction for speed of sound in liquidYes
DisplayQVGA 2.0 model: color LCD, status indicator light
Display update cycleApprox. 10 times/second
Display resolution - Instantaneous flow0.01/0.1/1 (L/min) (default value: 0.1)
Display resolution - Integrated flow0.01/0.1/1 (L) (default value: 0.1; up to 8 digits)
Response time0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s
Measurement accuracyBetween 10 and 100% of F.S.: ±3.0% of RD*4*5Between 0 and 10% of F.S.: ±0.3% of F.S.*4*5
Repeatability0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*4*6
HysteresisVariable
Flow unitsL/min m3/h G/min
Pulse output increments (L)0.02–999.99
Pipe temperature measurement accuracy
Network supportIO-Link*7
Heat calculation function - UnitMJ/h kW kBTU/h*8
Heat calculation function - Display resolutionInstantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*8
Heat calculation function - Pulse output increments (MJ)0.02–999.99*8
Data accumulation - Accumulation periodApprox. 1 year
Data accumulation - Data readingUSB2.0
Power I/O connectorM12 8-pin connector (male)
I/O (switchable) - Output (Ch1/2/3/4)Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less
I/O (switchable) - Analog output (Ch1/2)4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less
I/O (switchable) - External input (Ch2/3)Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more
Power supply - Power voltage20–30 VDC, ripple (P-P) 10% included, Class 2/LPS
Power supply - Current consumption240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*9
Protection circuitProtection against reverse power connection, power supply surges, output short circuits, and output surges
Environmental resistance - Enclosure ratingIP65/67 (IEC 60529)*10
Environmental resistance - Ambient temperatureSensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2
Environmental resistance - Relative humidity35–85% RH (no condensation)
Environmental resistance - Vibration resistance10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions
Environmental resistance - Shock resistance100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes
Material - Display unitBody: PPS/PET/POM; Display window: PAR
Material - Sensor headBody: PEEK/PPS/PET/PAR/SUS304Sensor element: special rubber; Mounting bracket: SUS304/SUSXM7
Weightapprox. 490 g 17.28 oz

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence FD-H10K”