Fast delivery within 72 Hours

Keyence FD-G80L

Clamp-On Gas Flow Meter DN 65A/80A. FD-G80L. Series: Clamp-On Gas Flow Meter. Series code: FD-G series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Clamp-On Gas Flow Meter DN 65A/80A. FD-G80L. Series: Clamp-On Gas Flow Meter. Series code: FD-G series

Specification

Model Name

Clamp-On Gas Flow Meter DN 65A/80A

Model Code

FD-G80L

Series Title

Clamp-On Gas Flow Meter

Series Code

FD-G series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57345&dlModelId=PM_160G80L&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/process/flow/fd-g/downloads/?mode=cd&modelId=PM_160G80L

Manuals URL

https://www.keyence.com/products/process/flow/fd-g/downloads/?mode=ma&modelId=PM_160G80L

Model

FD-G80L

Pipe size - DN (Diameter Nominal)

65 A, 80 A

Pipe size - NPS (Nominal Pipe Size)

2 1/2", 3"

Pipe size - Outer diameter of pipe

ø72 to 78 mm 2.83" to 3.07", ø86 to 92 mm 3.39" to 3.62"

Pipe size - Pipe thickness

2.0 to 4.0 mm 0.08" to 0.16"

Supported pipe materials

Iron, steel, stainless steel

Supported fluids

Air, Nitrogen, other gases*1

Fluid temperature

0 to 60ºC 32 to 140 °F

Rated velocity of flow range

Up to 15 m/s

Actual flow rate range (typical) - m3/h

Pipe size 65 A: 200.0Pipe size 80 A: 280.0

Actual flow rate range (typical) - L/min

Pipe size 65 A: 3300Pipe size 80 A: 4600

Actual flow rate range (typical) - CFM

Pipe size 65 A: 120.00Pipe size 80 A: 160.00

Standard flow rate range (typical) [CFM] - 20°C 68°F 60 psi 0.41 MPa

Pipe size 65 A: 568.43Pipe size 80 A: 757.91

Standard flow rate range (typical) [CFM] - 20°C 68°F 80 psi 0.55 MPa

Pipe size 65 A: 720.64Pipe size 80 A: 960.85

Standard flow rate range (typical) [CFM] - 20°C 68°F 100 psi 0.69 MPa

Pipe size 65 A: 872.84Pipe size 80 A: 1163.79

Standard flow rate range (typical) [CFM] - 20°C 68°F 120 psi 0.83 MPa

Pipe size 65 A: 1025.05Pipe size 80 A: 1366.73

Display

QVGA 2.2" LCD color monitor

Display update cycle

Approx. 3 Hz

Display resolution - Instantaneous flow rate

0.1 m3/h, 1 L/min, 0.01 CFM

Display resolution - Consumption/leakage amount

0.01 m3, 1 L, 1 CF

Response time

1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)

Measurement accuracy - Between 10 and 100% of F.S.

±2.0% of RD*2*3*4*5

Measurement accuracy - Between 1 and 10% of F.S.

±1.0% of F.S.*2*3*4*5

Zero point error

±0.15% of F.S.*2*6

Static leakage repeatability

±1.0% of RD*4*7

Hysteresis

Variable

Flow units

CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min

I/O wiring connection port

M12 4-pin connector (male)

Detection mode (switchable) - ch.1

Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8

Detection mode (switchable) - ch.2

Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8

Standard I/O (switchable) - Control output (ch.1/ch.2)

NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less

Standard I/O (switchable) - Analog output (ch.2)

4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less

Standard I/O (switchable) - External input (ch.2)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output

Analog input (for volume conversion)

M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less

Power supplied to pressure sensor

Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)

Communication interface - USB

USB 2.0

Communication interface - Ethernet

IEEE 802.3u (100BASE-TX)

Communication interface

100 Mbps

Network function

Modbus TCP, EtherNet/IP™, IO-Link*9

Recording capacity - Consumption amount/ leakage amount

Approx. 5 years

Recording capacity - Events

100

Power supply - Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2

Power supply - Power consumption

350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)

Environmental resistance - Enclosure rating

IP65/67 (IEC 60529)*10

Environmental resistance - Ambient temperature

Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)

Environmental resistance - Relative humidity

5 to 85%RH (no condensation)

Environmental resistance - Vibration resistance

10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes

Environmental resistance - Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material - Display unit

Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating

Material - Detection head

Body: PPS/SUS304, rear surface: rubber

Material - Mounting/damping bracket

SUS304

Weight

Approx. 3.6 kg

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.