Keyence FD-G80

Clamp-On Gas Flow Meter DN 65A/80A. FD-G80. Series: Clamp-On Gas Flow Meter. Series code: FD-G series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Clamp-On Gas Flow Meter DN 65A/80A. FD-G80. Series: Clamp-On Gas Flow Meter. Series code: FD-G series

Specification

Model NameClamp-On Gas Flow Meter DN 65A/80A
Model CodeFD-G80
Series TitleClamp-On Gas Flow Meter
Series CodeFD-G series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57345&dlModelId=PM_160G80&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/fd-g/downloads/?mode=cd&modelId=PM_160G80
Manuals URLhttps://www.keyence.com/products/process/flow/fd-g/downloads/?mode=ma&modelId=PM_160G80
ModelFD-G80
Pipe size - DN (Diameter Nominal)65 A, 80 A
Pipe size - NPS (Nominal Pipe Size)2 1/2″, 3″
Pipe size - Outer diameter of pipeø72 to 78 mm 2.83″ to 3.07″, ø86 to 92 mm 3.39″ to 3.62″
Pipe size - Pipe thickness2.9 to 6.3 mm 0.114″ to 0.25″
Supported pipe materialsIron, steel, stainless steel
Supported fluidsAir, Nitrogen, other gases*1
Fluid temperature0 to 60ºC 32 to 140 °F
Rated velocity of flow rangeUp to 15 m/s
Actual flow rate range (typical) - m3/hPipe size 65 A: 200.0Pipe size 80 A: 280.0
Actual flow rate range (typical) - L/minPipe size 65 A: 3300Pipe size 80 A: 4600
Actual flow rate range (typical) - CFMPipe size 65 A: 120.00Pipe size 80 A: 160.00
Standard flow rate range (typical) [CFM] - 20°C 68°F 60 psi 0.41 MPaPipe size 65 A: 568.43Pipe size 80 A: 757.91
Standard flow rate range (typical) [CFM] - 20°C 68°F 80 psi 0.55 MPaPipe size 65 A: 720.64Pipe size 80 A: 960.85
Standard flow rate range (typical) [CFM] - 20°C 68°F 100 psi 0.69 MPaPipe size 65 A: 872.84Pipe size 80 A: 1163.79
Standard flow rate range (typical) [CFM] - 20°C 68°F 120 psi 0.83 MPaPipe size 65 A: 1025.05Pipe size 80 A: 1366.73
DisplayQVGA 2.2″ LCD color monitor
Display update cycleApprox. 3 Hz
Display resolution - Instantaneous flow rate0.1 m3/h, 1 L/min, 0.01 CFM
Display resolution - Consumption/leakage amount0.01 m3, 1 L, 1 CF
Response time1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
Measurement accuracy - Between 10 and 100% of F.S.±2.0% of RD*2*3*4*5
Measurement accuracy - Between 1 and 10% of F.S.±1.0% of F.S.*2*3*4*5
Zero point error±0.15% of F.S.*2*6
Static leakage repeatability±1.0% of RD*4*7
HysteresisVariable
Flow unitsCFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min
I/O wiring connection portM12 4-pin connector (male)
Detection mode (switchable) - ch.1Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8
Detection mode (switchable) - ch.2Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8
Standard I/O (switchable) - Control output (ch.1/ch.2)NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less
Standard I/O (switchable) - Analog output (ch.2)4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less
Standard I/O (switchable) - External input (ch.2)Short-circuit current: 1.5 mA or less, input time: 20 ms or more
Protection circuitPower supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output
Analog input (for volume conversion)M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less
Power supplied to pressure sensorSupply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)
Communication interface - USBUSB 2.0
Communication interface - EthernetIEEE 802.3u (100BASE-TX)
Communication interface100 Mbps
Network functionModbus TCP, EtherNet/IP™, IO-Link*9
Recording capacity - Consumption amount/ leakage amountApprox. 5 years
Recording capacity - Events100
Power supply - Power voltage20 to 30 VDC including 10% ripple (P-P), Class 2
Power supply - Power consumption350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)
Environmental resistance - Enclosure ratingIP65/67 (IEC 60529)*10
Environmental resistance - Ambient temperatureDetection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)
Environmental resistance - Relative humidity5 to 85%RH (no condensation)
Environmental resistance - Vibration resistance10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes
Environmental resistance - Shock resistance100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis
Material - Display unitBody: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating
Material - Detection headBody: PPS/SUS304, rear surface: rubber
Material - Mounting/damping bracketSUS304
WeightApprox. 3.6 kg