B&R XEPIMC200.02

CPU I/O board, ARM Cortex-A9, 667 MHz, 2 GB flash memory, 512 MB DDR3L SDRAM, 64 kB FRAM, 24 VDC, 2x Ethernet interface, 1x CAN bus, 1x RS485 interface, 1x USB 2.0 interface, 1x POWERLINK interface, 1…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

CPU I/O board, ARM Cortex-A9, 667 MHz, 2 GB flash memory, 512 MB DDR3L SDRAM, 64 kB FRAM, 24 VDC, 2x Ethernet interface, 1x CAN bus, 1x RS485 interface, 1x USB 2.0 interface, 1x POWERLINK interface, 1x X2X Link interface, 43 digital inputs, 24 VDC, sink/source, 2 event counters or gate time / period measurement, 33 digital outputs, 24 VDC, 2 A (50%), 20 digital outputs, 24 VDC, 0.5 A, 2 PWM outputs, 3 A, 8 thermocouple inputs J, K, S, N, 4 analog inputs for potentiometers, 0 to 10 V, 0 to 20 mA, 4.5 V, 14-bit, 2 analog inputs ±10 V, 14-bit, 7 analog outputs, ±10 V, 12-bit

Specification

I/O module43 digital inputs, 6 analog inputs, 53 digital outputs, 7 analog outputs, 8 thermocouples, 2 PWM outputs
Interfaces2x Ethernet, 1x CAN bus, 1x RS485 interface, 1x POWERLINK, 1x X2X Link, 1x USB
B&R ID code0xF730
Automation Studio4.5.01 or later
Automation RuntimeB4.53 or later
CoolingPassive
Quantity7
StateSupply voltage OK, operating state, module status, Ethernet, CAN, RS485, POWERLINK, X2X Link
Power buttonNo
Reset buttonYes
Master capabilityNo
BuzzerNo
ACOPOS supportNo
Visual Components supportNo
Safety supportNo
Electrical isolationThermocouples, Ethernet 1 (IF2), Ethernet 2 (IF3), POWERLINK (IF9) and X2X (IF10) isolated from each other and from other interfaces Power supply not isolated from channel, and channel not isolated from channel
CEYes
CRA (Cyber Resilience Act)In preparation
BootloaderAutomation Runtime: A4.11
CompactFlash slot
Real-time clockYes, 1 s resolution, >±10 ppm accuracy at 25°C
FPUYes
TypePush/Pull
Clock frequency667 MHz
Data code24 kB
Program code32 kB
L2 cache256 kB
Mode/Node switchesNo
Remanent variables64 kB FRAM, retention >10 years
Shortest task class cycle time1 ms
Typical instruction cycle time0.01 μs
RAM512 MB DDR3 SDRAM
Data retention10 years
Guaranteed40 TB
Results for 5 years21.9 GB/day
Guaranteed erase/write cycles20,000
Error-correcting code (ECC)Yes
Temperature cutoffYes
Connection designationX6 X2X
Variant0TB1104.9000
Line lengthMax. 100 m between 2 nodes (segment length)
Max. transfer rate10/100 Mbit/s
Physical layer100BASE-TX
Half-duplexYes
Full-duplexNo
AutonegotiationYes
Auto-MDI/MDIXYes
Current-carrying capacity0.5 A
Transfer rateMax. 100 Mbit/s
FieldbusPOWERLINK managing or controlled node
Number of stationsMax. 253
Internal bus power supplyNo
Network topologyLine
Distance between 2 stationsMax. 100 m
Nominal voltage24 VDC
Input voltage24 VDC ±20%
Input current at 24 VDC3.2 mA
Additional functionsEvent counter, gate and period measurement
CircuitSink or source
Input delayCounter inputs 1 to 2: <4 µs Inputs 3 to 41: <1 ms
Low<5 V
High>15 V
Signal formSquare wave pulse
EvaluationPositive or negative edge
Input frequencyMax. 100 kHz
Pulse length10 µs
Counter size16-bit
Supported inputsInput 1: Counter 1 Input 2: Counter 2
InternalYes
ExternalMax. 100 kHz
Length of pause between pulses10 µs
InputInputs 1 and 2: ±10 V Inputs 3 to 6: 0 to 10 V, 0 to 20 mA or 0 to 100% (Upot)
Input typeInputs 1 and 2: Differential input Inputs 3 to 6: Single-ended input
Digital converter resolution12-bit
Data typeINT
VoltageINT 0x8000 – 0x7FFF / 1 LSB = 0x0010 = 4.88 mV
Current0.004 %/°C
Input impedance in signal range10 MΩ
Current channel load<400 Ω
Input protectionProtection against wiring with supply voltage
Gain0.080%, based on the current output value
Offset0.050%, based on the entire output range
Supply voltage UPot for potentiometer4.5 V / Max. 50 mA
Measurement range0.5 to 10 kΩ
Cutoff frequencyInputs 1 and 2: 1 kHz Inputs 3 to 6: 10 kHz
Slope60 dB
Output formatINT
FeCuNi: Type J-210 to 1200°C
NiCrNi: Type K-270 to 1372°C
NiCrSi: Type N-270 to 1300°C
PtRhPt: Type S-50 to 1768°C
Sensor temperature0.1°C/LSB
Type J: Fe-CuNi±0.14% at 25°C
Type K: NiCr-Ni±0.18% at 25°C
Type N: NiCrSi-NiSi±0.16% at 25°C
Type S: PtRh10-Pt±0.34% at 25°C
Nominal output currentScrew clamp terminal blocks X12, X13 and X15: Per output: 2 A Per group: 2 A Per screw clamp terminal block: 11 A Screw clamp terminal blocks X14 and X16: Per output: 0.5 A
Output circuitSink
Output protectionProtection against wiring with supply voltage, short-circuit proof
SupplyExternal
FuseNo internal fuse, the power supply of the outputs of each connector must be protected using a separate fuse of max. 15 A.
Switching frequency (resistive load)Max. 100 Hz
Switching delayMax. 500 µs
Supply voltageSeparately for each connector: 12 to 24 VDC ±20%
Supply voltage (permissible range)External, 11 to 28 VDC
Nominal current3 A
Maximum load current3.5 A / output
Resistive load≥8 Ω
Inductive load≤10 mH
PWM frequency15 Hz to 50 kHz
Configurable ditherAmplitude (8-bit), frequency (2 to 500 Hz)
Period duration resolution16-bit
PWM mode15-bit + sign ≥1 µs
Current mode15-bit + sign
Output±10 V
Switch on/off behaviorInternal enable relay, for startup
-10 V0x8000
0 V0x0000
Max. load per output±10 mA (load ≥1 kΩ)
Max. gain drift0.08%, based on the current output value
Max. offset drift0.05%, based on the entire output range
Error caused by load change0.015% from 10 MΩ → 1 kΩ, resistive
Nonlinearity0.025%, based on the output range
Voltage range24 VDC ±25%
Power consumption6.5 W
Voltage monitoringYes
HorizontalNo
VerticalYes
Pollution degree per EN 60664-12
Operation10 to 90%, non-condensing
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Width190 mm
Height198 mm
Depth31 mm
Module dimensions including mounting plates190 x 198 x 31 mm (W x H x D)