Fast delivery within 72 Hours

B&R X67BC6321.L12

Fieldbus: PROFIBUS DPIntegrated Y-connector for fieldbus connection16 digital channels, configurable as inputs or outputsM12 connectionsSimple I/O configuration via the fieldbusIntegrated connection t…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Fieldbus: PROFIBUS DPIntegrated Y-connector for fieldbus connection16 digital channels, configurable as inputs or outputsM12 connectionsSimple I/O configuration via the fieldbusIntegrated connection to local expansions via X2X Link for 63 additional modulesConfigurable I/O cycle (0.2 to 1 ms)

PROFIBUS DP is based on the physics of the RS485 interface. Data transfer is controlled using a hybrid bus access procedure: Active stations receive communication rights via a token passing procedure and can then access all stations on the network according to the master-slave principle. The maximum time of circulation for a token can be configured, which results in a defined cycle time.Access represents various services for the user for both cyclic and for acyclic data transfer.This bus controller makes it possible to connect X2X Link I/O nodes to PROFIBUS DP. It supports PROFIBUS DP with all of its options and other additional properties. In addition to the device, module and channel diagnostics provided in the PROFIBUS standard, it is also possible, for example, to switch to the slot diagnostics option in S7 format. X67 or other modules based on X2X Link can be connected to the bus controller. The configuration of the modular system is optimally supported by PROFIBUS DP.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).

Specification

Bus controller0x1AEC
Inputs/Outputs8x M12, A-coded
Insulation voltage between channel and bus500 Veff
Nominal voltage24 VDC
Internal I/O module0x1A1D
Sensor/Actuator power supplyMax. 12 W
Status indicatorsI/O function per channel, supply voltage, bus function
OutputsYes, using LED status indicator and software
I/O power supplyM8, 4-pin
FieldbusNo limitation
Power output15 W X2X Link power supply for I/O modules
Internal I/O2.04 W
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 – Max. 60°C TÜV 05 ATEX 7201X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
KCYes
VariantCurrent-sourcing FET
Max. distance1200 m
Transfer rateMax. 12 Mbit/s
Default transfer rateAutomatic transfer rate detection
Synchronization between bus systems possibleNo
PROFIBUS DP ID0xBC61
Terminating resistorCan be optionally screwed onto the integrated Y-connector
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 2 VDC
Summation currentMax. 0.5 A
Short-circuit proofYes
Input characteristics per EN 61131-2Type 1
Input voltage18 to 30 VDC
Input current at 24 VDCTyp. 4 mA
Input circuitSink
Hardware≤10 μs (channels 1 to 4) / ≤70 µs (channels 5 to 16)
SoftwareDefault 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals
Input resistanceTyp. 6 kΩ
Additional functions50 kHz event counting, gate measurement
Low<5 VDC
High>15 VDC
Quantity1
Signal formSquare wave pulse
EvaluationPositive edge – Negative edge
Input frequencyMax. 50 kHz
Counter 1Input 1
Counter 2Input 3
Counter frequencyMax. 50 kHz
Counter size16-bit
Internal48 MHz, 3 MHz, 187.5 kHz
Length of pause between pulses≥100 µs
Pulse length≥20 µs
Supported inputsInput 2 or input 4
Switching voltageI/O power supply minus residual voltage
Nominal output current0.5 A
Total nominal current8 A
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 µA
Switching on after overload shutdownApprox. 10 ms (depends on the module temperature)
Residual voltage<0.3 V at 0.5 A nominal current
Peak short-circuit current<12 A
0 → 1<400 µs
1 → 0<400 µs
Resistive loadMax. 100 Hz
Inductive loadSee section “Switching inductive loads”.
Braking voltage when switching off inductive loads50 VDC
Electrical isolationChannel isolated from PROFIBUS and bus PROFIBUS not isolated from bus and channel not isolated from channel
AnyYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Operation-25 to 60°C
Derating
Storage-40 to 85°C
Transport-40 to 85°C
Width53 mm
Height155 mm
Depth42 mm
Weight375 g
M8Max. 0.4 Nm
M12Max. 0.6 Nm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X67BC6321.L12”

Your email address will not be published. Required fields are marked *