Fast delivery within 72 Hours

B&R X67AO1223

4 analog outputs ±10 VIntegrated enable relay for initial phaseVery short cycle timesOptimal shield grounding on all channels

The module is equipped with 4…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

4 analog outputs ±10 VIntegrated enable relay for initial phaseVery short cycle timesOptimal shield grounding on all channels

The module is equipped with 4 inputs with 12-bit digital converter resolution. The output signal range is ±10 V.

Specification

I/O module4 analog outputs ±10 V
B&R ID code0x16F3
Status indicatorsI/O function per channel, supply voltage, bus function
I/O power supplyM8, 4-pin
Outputs4x M12, A-coded
Internal I/O4 W
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 – Max. 60°C TÜV 05 ATEX 7201X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
KCYes
Nominal voltage24 VDC
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
Actuator power supplyMax. 12 W
Output±10 V
Digital converter resolution12-bit
Conversion time400 µs for all outputs
Settling time on output change over entire rangeApprox. 1 ms
Switch on/off behaviorInternal enable relay for startup and errors
Output protectionProtection against wiring with supply voltage, short-circuit proof
Output formatExample: INT 0x8001 – 0x7FFF / 1 LSB = 0x0010 = 4.882 mV
Load per channelMax. ±10 mA, load ≥ 1 kΩ
Output filterFirst-order low-pass filter / cutoff frequency 2.5 kHz
Max. gain drift0.012%/°C
Max. offset drift0.015%/°C
Error caused by load changeMax. 0.01%, from 10 MΩ → 1 kΩ, resistive
Nonlinearity<0.15%
Insulation voltage between channel and bus500 Veff
Output response when the power supply is switched on/offAn enable relay is switched on at a defined value ≠ 0, default setting = 10 kΩ to GND
Current limiting±40 mA
To actuator or I/O power supplyYes
To GNDYes
Gain0.15%
Offset0.05%
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 500 mAMax. 2 VDC
Summation currentMax. 0.5 A
Short-circuit proofYes
Electrical isolationChannel isolated from bus Channel not isolated from channel
AnyYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Operation-25 to 60°C
Derating
Storage-40 to 85°C
Transport-40 to 85°C
Width53 mm
Height85 mm
Depth42 mm
Weight190 g
M8Max. 0.4 Nm
M12Max. 0.6 Nm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X67AO1223”

Your email address will not be published. Required fields are marked *