Fast delivery within 72 Hours

B&R X20DS4389

 291,50

3 in stock

4 digital input channels4 digital channels, configurable as inputs or outputs4 edge detection units with timestamp function (each usable as pulse duration or differential time measurement, 4 history e…

3 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

4 digital input channels4 digital channels, configurable as inputs or outputs4 edge detection units with timestamp function (each usable as pulse duration or differential time measurement, 4 history elements per unit)4x precise edge generation down to the µs (up to four edges per unit in each case)4x oversampling (input and output signal)24 VDC and GND for sensor/actuator supplyNetTime timestamp: Input data, edge detection, edge generation

This module is a digital signal processor module that is used for detecting and evaluating input edges and for creating edges. An additional essential feature is the module’s integrated timestamp function. This allows fast input edges such as registration marks to be detected independently of the system’s X2X Link cycle time and provided with a precise input stamp. In the other direction, the module sets outputs at exactly specified times. This is done with a resolution up to 125 ns. In oversampling mode, the module acquires very short input patters whose low or high phases are shorter than the X2X Link cycle time. Similarly, output patterns (e.g. drum sequencers) can also be output with extremely short high/low times. Oversampling can take place with a scan rate of up to 25 μs. If necessary, up to 4 events per edge detection unit can be stored in a buffer (history elements). Other functions include pulse duration measuring and differential time measuring.

Specification

I/O module4 digital input channels, 4 digital channels configurable as inputs or outputs, 4 edge detection units with timestamp function (each usable as pulse duration or differential time measurement, 4 history elements per unit), 4x microsecond-accurate edge generation (each up to 4 edges per unit), 4x oversampling (input and output signal)
B&R ID code0xA93B
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software (output state)
Bus0.01 W
Internal I/O1.5 W
Additional power dissipation caused by actuators (resistive) [W]
Type of signal linesShielded lines must be used for all signal lines.
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
KCYes
Quantity4
Nominal voltage24 VDC
Input voltage24 VDC -15% / +20%
Input current at 24 VDCApprox. 1.3 mA
Input circuitSink
Input resistance18.4 kΩ
Additional functions4x microsecond-accurate edge generation, 4x output oversampling
Input frequency40 kHz
Low<5 VDC
High>15 VDC
Insulation voltage between channel and bus500 Veff
VariantPush / Pull / Push-Pull
Switching voltage24 VDC -15% / +20%
Nominal output current0.1 A
Total nominal current0.4 A
Output circuitSink and/or source
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
Diagnostic statusOutput monitoring
Leakage current when the output is switched offMax. 25 µA
RDS(on)150 mΩ
Residual voltage<0.9 V at 0.1 A nominal current
Peak short-circuit current<10 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 10 ms (depends on the module temperature)
0 → 1<2 µs
1 → 0<2 µs
Resistive loadMax. 24 kHz
Inductive loadSee section “Switching inductive loads”.
Braking voltage when switching off inductive loadsSwitching voltage + 0.6 VDC
Operating mode4 pulse duration measurements, relative or absolute moments of input edges in microsecond resolution, 4 history elements per unit
Counter size16/32-bit
Input frequency (max.)40 kHz
Resolution1 µs
Signal formSquare wave pulse
Sensor power supplyModule-internal, max. 600 mA
AbsoluteAbsolute to NetTime
RelativeRelative to other edges
Range of values16-bit or 32-bit value
Actuator power supplyModule-internal, max. 600 mA
Sample time25 to 255 µs
Data volumeUp to 64 bits per X2X Link cycle in the input and output direction
Electrical isolationChannel isolated from bus Channel not isolated from channel
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20DS4389”

Your email address will not be published. Required fields are marked *