4 digital input channels4 digital channels, configurable as inputs or outputs4 edge detection units with timestamp function (each usable as pulse duration or differential time measurement, 4 history e…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

4 digital input channels4 digital channels, configurable as inputs or outputs4 edge detection units with timestamp function (each usable as pulse duration or differential time measurement, 4 history elements per unit)4x precise edge generation down to the µs (up to four edges per unit in each case)4x oversampling (input and output signal)24 VDC and GND for sensor/actuator supplyNetTime timestamp: Input data, edge detection, edge generation

This module is a digital signal processor module that is used for detecting and evaluating input edges and for creating edges. An additional essential feature is the module’s integrated timestamp function. This allows fast input edges such as registration marks to be detected independently of the system’s X2X Link cycle time and provided with a precise input stamp. In the other direction, the module sets outputs at exactly specified times. This is done with a resolution up to 125 ns. In oversampling mode, the module acquires very short input patters whose low or high phases are shorter than the X2X Link cycle time. Similarly, output patterns (e.g. drum sequencers) can also be output with extremely short high/low times. Oversampling can take place with a scan rate of up to 25 μs. If necessary, up to 4 events per edge detection unit can be stored in a buffer (history elements). Other functions include pulse duration measuring and differential time measuring.

Specification

I/O module

4 digital input channels, 4 digital channels configurable as inputs or outputs, 4 edge detection units with timestamp function (each usable as pulse duration or differential time measurement, 4 history elements per unit), 4x microsecond-accurate edge generation (each up to 4 edges per unit), 4x oversampling (input and output signal)

B&R ID code

0xA93B

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Outputs

Yes, using LED status indicator and software (output state)

Bus

0.01 W

Internal I/O

1.5 W

Additional power dissipation caused by actuators (resistive) [W]

Type of signal lines

Shielded lines must be used for all signal lines.

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: B (0 to 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck)

CCS

Yes

LR

ENV1

KR

Yes

ABS

Yes

BV

EC33B
Temperature: 5 – 55°C
Vibration: 4 g
EMC: Bridge and open deck

KC

Yes

Quantity

4

Nominal voltage

24 VDC

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Approx. 1.3 mA

Input circuit

Sink

Input resistance

18.4 kΩ

Additional functions

4x microsecond-accurate edge generation, 4x output oversampling

Input frequency

40 kHz

Low

<5 VDC

High

>15 VDC

Insulation voltage between channel and bus

500 Veff

Variant

Push / Pull / Push-Pull

Switching voltage

24 VDC -15% / +20%

Nominal output current

0.1 A

Total nominal current

0.4 A

Output circuit

Sink and/or source

Output protection

Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads

Diagnostic status

Output monitoring

Leakage current when the output is switched off

Max. 25 µA

RDS(on)

150 mΩ

Residual voltage

<0.9 V at 0.1 A nominal current

Peak short-circuit current

<10 A

Switch-on in the event of overload shutdown or short-circuit shutdown

Approx. 10 ms (depends on the module temperature)

0 → 1

<2 µs

1 → 0

<2 µs

Resistive load

Max. 24 kHz

Inductive load

See section "Switching inductive loads".

Braking voltage when switching off inductive loads

Switching voltage + 0.6 VDC

Operating mode

4 pulse duration measurements, relative or absolute moments of input edges in microsecond resolution,
4 history elements per unit

Counter size

16/32-bit

Input frequency (max.)

40 kHz

Resolution

1 µs

Signal form

Square wave pulse

Sensor power supply

Module-internal, max. 600 mA

Absolute

Absolute to NetTime

Relative

Relative to other edges

Range of values

16-bit or 32-bit value

Actuator power supply

Module-internal, max. 600 mA

Sample time

25 to 255 µs

Data volume

Up to 64 bits per X2X Link cycle in the input and output direction

Electrical isolation

Channel isolated from bus

Channel not isolated from channel

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

See section "Derating".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.

Pitch

12.5+0.2 mm