8 digital outputs with 2 ARated voltage 12 VDCSource connection1-wire connectionPower feed integrated in the moduleIntegrated output protection

This module…

3 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

8 digital outputs with 2 ARated voltage 12 VDCSource connection1-wire connectionPower feed integrated in the moduleIntegrated output protection

This module is equipped with 8 outputs for 1-wire connections. The outputs are designed for a source circuit. The nominal output current is 2 A. The output supply is fed directly to the module. An additional supply module is not needed. There is no connection between the module and the I/O supply potential on the bus module.

Specification

I/O module8 digital outputs 12 VDC for 1-wire connections
B&R ID code0xA4AD
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software (output error status)
Supply voltage monitoringYes, using software
Bus0.22 W
Internal I/O
External I/O0.82 W
Additional power dissipation caused by actuators (resistive) [W]+4.48
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user’s manual)FTZÚ 09 ATEX 0083X
ULcULus E115267Industrial control equipment
HazLoccCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C)Humidity: B (up to 100%)Vibration: B (4 g)EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33BTemperature: 5 – 55°CVibration: 4 gEMC: Bridge and open deck
KCYes
VariantCurrent-sourcing FET
Nominal voltage12 VDC
Switching voltage12 VDC (-15% / +20%)
Nominal output current2 A
Total nominal current8 A
Connection type1-wire connections
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit (see value “Short-circuit peak current”)Internal freewheeling diode for switching inductive loads (see section “Switching inductive loads”) Reverse polarity protection of supply voltage
SupplyExternal
FuseRequired line fuse: Max. 10 A, slow-blow
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 μA
RDS(on)140 mΩ
Peak short-circuit current<12 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 10 ms (depends on the module temperature)
0 → 1<300 μs
1 → 0<300 μs
Resistive loadMax. 500 Hz, 600 Hz at max. 250 mA load
Inductive loadSee section “Switching inductive loads”.
Braking voltage when switching off inductive loadsTyp. 50 VDC
Insulation voltage between channel and bus500 Veff
Additional functionsOutputs can be connected in parallel to increase the output current.
Electrical isolationChannel isolated from bus and I/O power supply
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing