Fast delivery within 72 Hours

B&R X20cBC8084

POWERLINKI/O configuration and firmware update via the fieldbusIntegrated compact link selector function2 active hub expansion modules can be connected to the bus controllerRedundant supply possible…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

POWERLINKI/O configuration and firmware update via the fieldbusIntegrated compact link selector function2 active hub expansion modules can be connected to the bus controllerRedundant supply possible

The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.Systems with redundant cabling can be implemented easily using POWERLINK. Unlike ring redundancy, cable redundancy does not require cable looping, which can sometimes be problematic. This allows the creation of all types of tree structures. When using a device with the link selector function, data is always transferred via the highest quality network lines. The link selector function is integrated in the bus controller.

Specification

Bus controllerPOWERLINK (V1/V2) controlled node with compact link selector
B&R ID code0xDF10
Status indicatorsModule status, bus function
Module statusYes, using LED status indicator and software
Bus functionYes, using LED status indicator and software
Dynamic node allocation (DNA)Yes
Bus2 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
Fieldbus200 μs
TypeType 2
Variant2x shielded RJ45
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Physical layer100BASE-TX
Half-duplexYes
Full-duplexNo
AutonegotiationYes
Auto-MDI/MDIXYes
Hub propagation delay0.96 to 1 µs
Synchronization between bus systems possibleYes
Electrical isolationPOWERLINK isolated from bus and I/O
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Starting temperatureYes, -40°C
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
OperationUp to 100%, condensing
NoteOrder 1x terminal block X20TB12 separately. Order 1x power supply module X20cPS9400 separately. Order 1x bus base X20cBB80 or X20cBB82 separately
X20BB8037.5+0.2 mm