B&R X20cBC8084

POWERLINKI/O configuration and firmware update via the fieldbusIntegrated compact link selector function2 active hub expansion modules can be connected to the bus controllerRedundant supply possible…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

POWERLINKI/O configuration and firmware update via the fieldbusIntegrated compact link selector function2 active hub expansion modules can be connected to the bus controllerRedundant supply possible

The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.Systems with redundant cabling can be implemented easily using POWERLINK. Unlike ring redundancy, cable redundancy does not require cable looping, which can sometimes be problematic. This allows the creation of all types of tree structures. When using a device with the link selector function, data is always transferred via the highest quality network lines. The link selector function is integrated in the bus controller.

Specification

Bus controller

POWERLINK (V1/V2) controlled node with compact link selector

B&R ID code

0xDF10

Status indicators

Module status, bus function

Module status

Yes, using LED status indicator and software

Bus function

Yes, using LED status indicator and software

Dynamic node allocation (DNA)

Yes

Bus

2 W

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: B (0 to 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck)

LR

ENV1

KR

Yes

ABS

Yes

BV

EC33B
Temperature: 5 – 55°C
Vibration: 4 g
EMC: Bridge and open deck

Fieldbus

200 μs

Type

Type 2

Variant

2x shielded RJ45

Line length

Max. 100 m between 2 stations (segment length)

Transfer rate

100 Mbit/s

Physical layer

100BASE-TX

Half-duplex

Yes

Full-duplex

No

Autonegotiation

Yes

Auto-MDI/MDIX

Yes

Hub propagation delay

0.96 to 1 µs

Synchronization between bus systems possible

Yes

Electrical isolation

POWERLINK isolated from bus and I/O

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

Starting temperature

Yes, -40°C

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

Up to 100%, condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x power supply module X20cPS9400 separately.
Order 1x bus base X20cBB80 or X20cBB82 separately

X20BB80

37.5+0.2 mm

X20BB82

87.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20cBC8084”

Your email address will not be published. Required fields are marked *