Specification

B&R ID code0x2FA7
Automation Studio4.6.1.x or later
Dynamic node allocation (DNA)Yes
Cooling and mounting typeWall mounting
Slots for plug-in modules2
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ULcULus E225616 Power conversion equipment
KCYes
Network configurationsTT, TN-S, TN-C-S
Mains input voltage3x 220 to 3x 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Total harmonic distortion current (THDi)<0.2%
Total harmonic distortion voltage (THDu)<1%
Installed loadMax. 124 kW
Inrush current at 400 VACMax. 102 A
Switch-on interval>800 s
230 VAC69.7 mF
400 VAC23 mF
480 VAC16 mF
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 kHz
Integrated line filter per EN 61800-3, category C3No
Integrated regeneration chokeNo
RegenerativeYes
Power factor correction (PFC)Yes
Line fuseMax. 400 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 410 A (circuit breaker per EN 60947-2 or UL 489)
L1, L2, L3, PEM8 threaded bolts
Shield connectionYes
Flexible and fine-stranded wires
Terminal cable cross section dimension of shield connection32 to 50 mm
Nominal5 to 40°C
Continuous power (supply and regeneration)120 kW
Mains input voltage <3x 400 VAC600 W/V * (400 V – Mains input voltage)
UDC <750 VDCP * (1 – UDC/750)
Switching frequency 5 kHzIn preparation
Switching frequency 10 kHzIn preparation
Starting at 500 m above sea level12 kW per 1000 m
Peak power (supply and regeneration)240 kW
DC bus capacitance3630 µF
Overload protectionNo
Short-circuit and ground fault protectionNo
VariantACOPOSmulti backplane
Input voltage25 VDC ±1.6%
Input capacitance4.7 µF
Max. power consumption37 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF…
Quantity2
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC / 315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection250 mA (slow-blow) electronic, automatic reset
Output voltage24 V +5.8% / -0.1%
Continuous current4.2 A
Max. overcurrent limiting10 A
Short-circuit proofYes
Open-circuit monitoringNo
Undervoltage monitoringNo
CircuitSink
Input - Power supply moduleYes
Input - InputYes
Maximum55°C
Low<5 V
High>15 V
Input current at nominal voltageApprox. 10 mA
Rising edge52 μs ±0.5 μs (digitally filtered)
Falling edge53 μs ±0.5 μs (digitally filtered)
Modulation compared to ground potentialMax. ±38 V
Mapp Motion5.24.1 and higher
ACP10/ARNC05.24.1 and higher
Discharge capacitance1.8 µF
Power dissipation relative to continuous apparent powerIE2 (10,25) 0.2% IE2 (50,25) 0.3% IE2 (10,50) 0.2% IE2 (50,50) 0.5% IE2 (90,50) 0.9% IE2 (10,100) 0.3% IE2 (50,100) 0.9% IE2 (90,100) 2%
Nominal losses in standby mode15.5 W
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width427.5 mm
Height317 mm
Wall mounting263 mm
Weight24 kg
Module width8