Fast delivery within 72 Hours

B&R 8BVP1650HW00.004-3

ACOPOSmulti3 power supply module, 165 A, AS, wall mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOSmulti3 power supply module, 165 A, AS, wall mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Specification

B&R ID code

0x2FA7

Automation Studio

4.6.1.x or later

Dynamic node allocation (DNA)

Yes

Cooling and mounting type

Wall mounting

Slots for plug-in modules

2

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616
Power conversion equipment

KC

Yes

Network configurations

TT, TN-S, TN-C-S

Mains input voltage

3x 220 to 3x 480 VAC ±10%

Frequency

50 / 60 Hz ±4%

Total harmonic distortion current (THDi)

<0.2%

Total harmonic distortion voltage (THDu)

<1%

Installed load

Max. 124 kW

Inrush current at 400 VAC

Max. 102 A

Switch-on interval

>800 s

230 VAC

69.7 mF

400 VAC

23 mF

480 VAC

16 mF

Nominal switching frequency

5 kHz

Possible switching frequencies

5 / 10 kHz

Integrated line filter per EN 61800-3, category C3

No

Integrated regeneration choke

No

Regenerative

Yes

Power factor correction (PFC)

Yes

Line fuse

Max. 400 A (gG fuses per IEC 60269-1 or Class CC, J, T)
Max. 410 A (circuit breaker per EN 60947-2 or UL 489)

L1, L2, L3, PE

M8 threaded bolts

Shield connection

Yes

Flexible and fine-stranded wires

Terminal cable cross section dimension of shield connection

32 to 50 mm

Nominal

5 to 40°C

Continuous power (supply and regeneration)

120 kW

Mains input voltage <3x 400 VAC

600 W/V * (400 V – Mains input voltage)

UDC <750 VDC

P * (1 – UDC/750)

Switching frequency 5 kHz

In preparation

Switching frequency 10 kHz

In preparation

Starting at 500 m above sea level

12 kW per 1000 m

Peak power (supply and regeneration)

240 kW

DC bus capacitance

3630 µF

Overload protection

No

Short-circuit and ground fault protection

No

Variant

ACOPOSmulti backplane

Input voltage

25 VDC ±1.6%

Input capacitance

4.7 µF

Max. power consumption

37 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF…

Quantity

2

DC bus voltage (UDC): 260 to 315 VDC

25 VDC * (UDC / 315)

DC bus voltage (UDC): 315 to 800 VDC

24 VDC ±6%

Fuse protection

250 mA (slow-blow) electronic, automatic reset

Output voltage

24 V +5.8% / -0.1%

Continuous current

4.2 A

Max. overcurrent limiting

10 A

Short-circuit proof

Yes

Open-circuit monitoring

No

Undervoltage monitoring

No

Circuit

Sink

Input - Power supply module

Yes

Input - Input

Yes

Maximum

55°C

Low

<5 V

High

>15 V

Input current at nominal voltage

Approx. 10 mA

Rising edge

52 μs ±0.5 μs (digitally filtered)

Falling edge

53 μs ±0.5 μs (digitally filtered)

Modulation compared to ground potential

Max. ±38 V

Mapp Motion

5.24.1 and higher

ACP10/ARNC0

5.24.1 and higher

Discharge capacitance

1.8 µF

Power dissipation relative to continuous apparent power

IE2 (10,25) 0.2%
IE2 (50,25) 0.3%
IE2 (10,50) 0.2%
IE2 (50,50) 0.5%
IE2 (90,50) 0.9%
IE2 (10,100) 0.3%
IE2 (50,100) 0.9%
IE2 (90,100) 2%

Nominal losses in standby mode

15.5 W

Hanging vertically

Yes

Horizontal, face up

Yes

Standing horizontally

No

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Overvoltage category per EN 61800-5-1

III

Degree of protection per EN 60529

IP20

Storage

5 to 95%

Transport

Max. 95% at 40°C

Operation

5 to 85%

Width

427.5 mm

Height

317 mm

Wall mounting

263 mm

Weight

24 kg

Module width

8

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8BVP1650HW00.004-3”

Your email address will not be published. Required fields are marked *