Fast delivery within 72 Hours
B&R 8BVI0330HCSS.000-4
ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module, 33 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loo…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module, 33 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements
Specification
| B&R ID code | 0x2FD9 |
|---|---|
| Automation Studio | 4.6.1.x or later |
| Mapp Technology Package | mapp Safety 5.24.0 or later |
| Cooling and mounting type | Cold plate or pass-through mounting |
| Slots for plug-in modules | 2 |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| Functional safety | Yes (openSAFETY) |
| UL | cULus E225616 Power conversion equipment |
| KC | Yes |
| Nominal | 5 to 40°C |
| Continuous power consumption | 24.4 kW |
| Switching frequency 5 kHz | 25 m |
| Switching frequency 10 kHz | 25 m |
| Switching frequency 20 kHz | 25 m |
| DC bus capacitance | 990 µF |
| Variant | ACOPOSmulti backplane |
| Input voltage | 25 VDC ±1.6% |
| Input capacitance | 32.9 µF |
| Max. power consumption | 31 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake |
| Quantity | 1 |
| DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (UDC/315) |
| DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6% |
| Fuse protection | 250 mA (slow-blow) electronic, automatic reset |
| Continuous power per motor connection | 24 kW |
| Continuous current per motor connection | 33 Aeff |
| Cold plate mounting | 0.32 A/K (starting at -82°C) |
| Pass-through mounting | 209 mm |
| Starting at 500 m above sea level | 3.3 Aeff per 1000 m |
| Peak current | 83 Aeff |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Overload protection | Yes |
| Short-circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| U, V, W, PE | Connector |
| Shield connection | Yes |
| With wire end sleeve | 0.5 to 16 mm² |
| UL/C-UL-US | 20 to 6 |
| CSA | 20 to 6 |
| Terminal cable cross section dimension of shield connection | 23 to 35 mm |
| Output voltage | Typ. 12.5 V |
| Continuous current per connection | 4.2 A |
| Max. internal resistance | 0.15 Ω |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 3 Ws |
| Max. switching frequency | 0.5 Hz |
| Overload and short-circuit protection | Yes |
| Open-circuit monitoring | Yes |
| Undervoltage monitoring | Yes |
| Response threshold for open-circuit monitoring | Approx. 0.5 A |
| Response threshold for undervoltage monitoring | 24 VDC -2% / -4% |
| Type | EnDat 2.2 |
| Connections | 9-pin female DSUB connector |
| Status indicators | UP/DN LEDs |
| Encoder - ACOPOSmulti | No |
| Encoder monitoring | Yes |
| Max. encoder cable length | 100 m Depends on the cross section of the power supply wires in the encoder cable |
| Load capacity | 350 mA |
| Short-circuit proof | Yes |
| Overload-proof | Yes |
| Signal transmission | RS485 |
| Data transfer rate | 6.25 Mbit/s |
| Max. power consumption per encoder interface | PSMC[W] = 19 V * IEncoder[A] |
| Circuit | Sink |
| Input - Inverter module | Yes |
| Input - Input | Yes |
| Maximum | 55°C |
| Low | <5 V |
| High | >15 V |
| Input current at nominal voltage | Approx. 10 mA |
| Rising edge | 52 µs ±0.5 µs (digitally filtered) |
| Falling edge | 53 µs ±0.5 µs (digitally filtered) |
| Modulation compared to ground potential | Max. ±38 V |
| Resistance range | 500 Ω to 5 kΩ |
| Mapp Motion | 5.24.1 and higher |
| ACP10/ARNC0 | 5.24.1 and higher |
| Discharge capacitance | 0.22 µF |
| Power dissipation relative to continuous apparent power | IE2 (10,25) 1.2% IE2 (50,25) 1.2% IE2 (10,50) 1.4% IE2 (50,50) 1.4% IE2 (90,50) 1.4% IE2 (10,100) 2.1% IE2 (50,100) 2.1% IE2 (90,100) 2.1% |
| Nominal losses in standby mode | 12 W |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | No |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
| Storage | 5 to 95% |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85% |
| Width | 106.5 mm |
| Height | 317 mm |
| Cold plate | 212 mm |
| Weight | Approx. 4.3 kg |