Fast delivery within 72 Hours

B&R 8BVI0014HCS0.000-3

ACOPOSmulti3 inverter module, 1.9 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

ACOPOSmulti3 inverter module, 1.9 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Specification

B&R ID code0x2F4E
Automation Studio4.6.1.x or later
Cooling and mounting typeCold plate or pass-through mounting
Slots for plug-in modules2
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
Functional safetyYes
ULcULus E225616 Power conversion equipment
KCYes
Nominal5 to 40°C
Continuous power consumption1.46 kW
Switching frequency 5 kHz25 m
Switching frequency 10 kHz25 m
Switching frequency 20 kHz10 m
DC bus capacitance165 µF
VariantACOPOSmulti backplane
Input voltage25 VDC ±1.6%
Input capacitance23.5 µF
Max. power consumption12 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake
Quantity1
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection250 mA (slow-blow) electronic, automatic reset
Continuous power per motor connection1.4 kW
Continuous current per motor connection1.9 Aeff
Cold plate mounting0.13 A/K (starting at 46°C)
Pass-through mounting209 mm
Starting at 500 m above sea level0.19 Aeff per 1000 m
Peak current4.7 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Overload protectionYes
Short-circuit and ground fault protectionYes
Max. output frequency598 Hz
U, V, W, PEConnector
Shield connectionYes
With wire end sleeve0.25 to 6 mm²
UL/C-UL-US30 to 10 AWG
CSA28 to 10 AWG
Terminal cable cross section dimension of shield connection12 to 22 mm
Output voltage24 VDC +5.8% / -0%
Continuous current per connection1.1 A
Max. internal resistance0.5 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Overload and short-circuit protectionYes
Open-circuit monitoringYes
Undervoltage monitoringYes
Response threshold for open-circuit monitoringApprox. 0.25 A
Response threshold for undervoltage monitoring24 VDC +0% / -4%
CircuitSink
Input - Inverter moduleYes
Input - InputYes
Maximum55°C
Input current at nominal voltageApprox. 10 mA
Low<5 V
High>15 V
Enable 1 → 0, PWM offMax. 20.5 ms
Enable 0 → 1, ready for PWMMax. 100 µs
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsPermitted Max. test pulse length: 500 µs
Rising edge52 µs ±0.5 µs (digitally filtered)
Falling edge53 µs ±0.5 µs (digitally filtered)
Resistance range500 Ω to 5 kΩ
Mapp Motion5.24.1 and higher
ACP10/ARNC05.24.1 and higher
Discharge capacitance0.14 µF
Power dissipation relative to continuous apparent powerIE2 (10,25) 4.4% IE2 (50,25) 4.4% IE2 (10,50) 4.6% IE2 (50,50) 4.6% IE2 (90,50) 4.6% IE2 (10,100) 5.1% IE2 (50,100) 5.1% IE2 (90,100) 5.1%
Nominal losses in standby mode8.5 W
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width53 mm
Height317 mm
Cold plate212 mm
WeightApprox. 2.1 kg
Module width1

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 8BVI0014HCS0.000-3”