Fast delivery within 72 Hours

B&R 80SD100XD.C011-01

Control for 2 stepper motors (2-phase bipolar, full bridge)256 microsteps per step2 Hiperface encoder inputs2 trigger inputsMotor holding brake connectionEnable inputAutomatic motor identificationHold…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Control for 2 stepper motors (2-phase bipolar, full bridge)256 microsteps per step2 Hiperface encoder inputs2 trigger inputsMotor holding brake connectionEnable inputAutomatic motor identificationHolding, boost and continuous current can be defined independent of one another

ACOPOSmicro stepper motor module, X2X Link interface, 2x HIPERFACE encoder, 24-64 VDC ±25% power supply, 2 motor connections, 10 A continuous current, 2 digital inputs 24 VDC, sink, can be used as trigger inputs, 1 digital output 24 VDC, 1 A, order terminal blocks separately!

Specification

Stepper motor module

Connection for 2 stepper motors with HIPERFACE encoder, 2-phase bipolar

B&R ID code

0xB177

Status indicators

X2X Link, operating state, module status, motor information

Module run/error

Yes, using LED status indicator and software

Module temperature / Cooling unit temperature

Yes, using software

Motor status

Yes, using LED status indicator and software

CPU - 24 VDC power supply

No

CPU - Power supply

Yes

CPU - Motor connection

Yes

CPU - Digital inputs

Yes

CPU - Enable inputs

Yes

CPU - Encoder

No

CPU - Motor holding brake

No

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E225616
Power conversion equipment

KC

Yes

Input voltage

24 VDC ±25%

Voltage monitoring

Yes

CPU

Max. 8 W

Reverse polarity protection

Yes

Inrush current

Max. 10 A

Idle (no motor powered)

Max. 0.5 W

Full load

See diagram "Dimensioning – Power dissipation from the power unit for each powered axis"

Inrush current limiting

Yes, PTC (min. 9 Ω), is bypassed during operation by means of relay contact.

Undervoltage cutoff

<18 VDC

Overvoltage cutoff

>95 VDC

Voltage measurement

Yes

Line protection

Must occur externally

Quantity

2

Nominal current

10 APeak

Max. current/motor

15 APeak (2 s)

Max. current/module

30 APeak

Nominal switching frequency

38.5 kHz

Max. motor line length

25 m

Step resolution

256 microsteps per full step

DC bus capacitance

940 µF

Nominal voltage

24 VDC

Continuous current per connection

1 A

Max. internal resistance

0.3 Ω

Resistive load

100 Hz

Inductive load

See section "Switching inductive loads"

Overload and short-circuit protection

Yes

Open-circuit monitoring

No

Undervoltage monitoring

Yes

Max. overcurrent limiting

8 A

Response threshold for undervoltage monitoring

≤11 VDC

Reference potential

GND for module power supply (X2 terminal, pin 10)

Variant

4-pin male connector

Type

HIPERFACE

Max. encoder cable length

25 m

Output voltage

Typ. 11.5 V

Load capacity

200 mA

Signal transmission

Differential signal, asymmetrical

Signal frequency

200 kHz

Differential voltage

0.5 to 1.25 Vss

Common-mode voltage

Max. ±7 V

Terminating resistor

120 Ω

ADC resolution

16 bits per sine/cosine period

Bit width of position value

Max. 32-bit

Baud rate

Configurable (max. 38.4 kbaud)

Input current at nominal voltage

Approx. 7.5 mA

Input circuit

Sink

Low

<5 VDC

High

>15 VDC

Maximum

30 VDC

Insulation voltage between input and bus

500 Veff

Input capacitance

10 nF (Rev. < K0: 100 µF)

Additional functions

Can be used as trigger input

Nominal

24 VDC

Input resistance

Approx. 3.2 kΩ

Rising edge

[Instant recording] Typ. 3 µs

Falling edge

[Instant recording] Typ. 4 µs

Input - ACOPOS

Yes, 500 Veff

Input - Input

Yes, 500 Veff

Modulation compared to ground potential

Max. ±38 V

Horizontal

No

Vertical

Yes

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Degree of protection per EN 60529

IP20

Operation

5 to 85 %, non-condensing

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Note

Order terminal blocks and cables separately!

Mounting/Cooling

Screw mounting with heat spreader on mounting plate or cold-plate.

Width

65 mm

Height

134 mm

Depth

95 mm

Weight

700 g

Backplane

Always mount on conductive and earthed backplane.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 80SD100XD.C011-01”

Your email address will not be published. Required fields are marked *