Fast delivery within 72 Hours
B&R 80PS080X3.10-01
Input: 3x 380 to 480 VAC ±10%Output voltage adjustable via X2X LinkStatus information readable via X2X LinkChopper output for connecting an external braking resistor3-phase wide range inputClosed meta…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Input: 3x 380 to 480 VAC ±10%Output voltage adjustable via X2X LinkStatus information readable via X2X LinkChopper output for connecting an external braking resistor3-phase wide range inputClosed metal housing
Power supply module, Input 3x 380-480 VAC ±10%, Power output 24-80 VDC 16.6 A (max. 1000 W), Output 24 VDC 2 A, X2X Link interface, integrated brake chopper, wall mounting. Order terminal blocks separately!
Specification
| B&R ID code | 0xA7A9 |
|---|---|
| Status LED | Yes |
| Bus | 0.8 W |
| Mains input - Power output | Yes |
| Mains input - 24 VDC | Yes |
| Power output - 24 VDC | No |
| X2X Link - Mains input | Yes |
| X2X Link - Power output | Yes |
| X2X Link - 24 VDC | Yes |
| Connection type | Maximum 25 m line length to the power supply module |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| UL | cULus E225616 Power conversion equipment |
| KC | Yes |
| Input voltage range | 3x 380 to 480 VAC ±10% |
| Input current at full load | 3x 2.2 A at 400 VAC 3x 1.8 A at 480 VAC |
| Frequency range of mains voltage | 50 to 60 Hz ±5% |
| Phase failure detector | Yes |
| Power failure bypass | 10 ms (at full load) |
| Power factor (cos φ) | 0.72 @ 400 V 1 kW 0.69 @ 480 V 1 kW |
| Leakage current to PE | <3.5 mA |
| Protective circuit | Transient surge protection with varistor |
| Internal | Each phase internally fused (5 A) |
| External | External fuse required for line protection |
| Output power | Max. 1000 W continuous power |
| Output protection | Short-circuit, overload and no-load proof |
| Control accuracy | ±2% |
| Power back immunity | Yes, <100 VDC |
| Output voltage | 24 to 80 VDC |
| 24 to 60 VDC | Max. 16.6 A continuous current |
| 60 to 80 VDC | Max. 16.6 to 12.5 A continuous current |
| Overload current | 20% overcurrent |
| Overload duration | 2 s |
| Switch-on time | <5 s (does not apply during firmware update) |
| Parallel connection | No |
| Series connection | No |
| Max. capacitive load | Unlimited |
| Voltage range | 24 VDC ±10% |
| Output current | Max. 2 A continuous current |
| Response threshold for chopper activation | 29 to 95 VDC (adjustable) |
| Overtemperature protection (chopper-internal) | Yes |
| Continuous current / Continuous power | 30 A |
| Maximum current / Maximum power | 40 A |
| Variant | 10-pin terminal block |
| Type | X2X Link |
| Min. X2X Link cycle time | 250 µs |
| Efficiency | >92% |
| Rated load | 90 W |
| No-load operation | 30 W |
| Vertical | Yes |
| Ventilation/Cooling | Internally controlled fan |
| Degree of protection per EN 60529 | IP20 |
| Operation | 5 to 95%, non-condensing |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Material | Robust metal housing |
| Width | 67.5 mm |
| Height | 257 mm |
| Depth | 219 mm |
| Weight | 3.75 kg |

Reviews