Fast delivery within 72 Hours
B&R 80PS080X3.10-01
Input: 3x 380 to 480 VAC ±10%Output voltage adjustable via X2X LinkStatus information readable via X2X LinkChopper output for connecting an external braking resistor3-phase wide range inputClosed meta…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Input: 3x 380 to 480 VAC ±10%Output voltage adjustable via X2X LinkStatus information readable via X2X LinkChopper output for connecting an external braking resistor3-phase wide range inputClosed metal housing
Power supply module, Input 3x 380-480 VAC ±10%, Power output 24-80 VDC 16.6 A (max. 1000 W), Output 24 VDC 2 A, X2X Link interface, integrated brake chopper, wall mounting. Order terminal blocks separately!
Specification
| B&R ID code |
0xA7A9 |
|---|---|
| Status LED |
Yes |
| Bus |
0.8 W |
| Mains input - Power output |
Yes |
| Mains input - 24 VDC |
Yes |
| Power output - 24 VDC |
No |
| X2X Link - Mains input |
Yes |
| X2X Link - Power output |
Yes |
| X2X Link - 24 VDC |
Yes |
| Connection type |
Maximum 25 m line length to the power supply module |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| UL |
cULus E225616 |
| KC |
Yes |
| Input voltage range |
3x 380 to 480 VAC ±10% |
| Input current at full load |
3x 2.2 A at 400 VAC |
| Frequency range of mains voltage |
50 to 60 Hz ±5% |
| Phase failure detector |
Yes |
| Power failure bypass |
10 ms (at full load) |
| Power factor (cos φ) |
0.72 @ 400 V 1 kW |
| Leakage current to PE |
<3.5 mA |
| Protective circuit |
Transient surge protection with varistor |
| Internal |
Each phase internally fused (5 A) |
| External |
External fuse required for line protection |
| Output power |
Max. 1000 W continuous power |
| Output protection |
Short-circuit, overload and no-load proof |
| Control accuracy |
±2% |
| Power back immunity |
Yes, <100 VDC |
| Output voltage |
24 to 80 VDC |
| 24 to 60 VDC |
Max. 16.6 A continuous current |
| 60 to 80 VDC |
Max. 16.6 to 12.5 A continuous current |
| Overload current |
20% overcurrent |
| Overload duration |
2 s |
| Switch-on time |
<5 s (does not apply during firmware update) |
| Parallel connection |
No |
| Series connection |
No |
| Max. capacitive load |
Unlimited |
| Voltage range |
24 VDC ±10% |
| Output current |
Max. 2 A continuous current |
| Response threshold for chopper activation |
29 to 95 VDC (adjustable) |
| Overtemperature protection (chopper-internal) |
Yes |
| Continuous current / Continuous power |
30 A |
| Maximum current / Maximum power |
40 A |
| Variant |
10-pin terminal block |
| Type |
X2X Link |
| Min. X2X Link cycle time |
250 µs |
| Efficiency |
>92% |
| Rated load |
90 W |
| No-load operation |
30 W |
| Vertical |
Yes |
| Ventilation/Cooling |
Internally controlled fan |
| Degree of protection per EN 60529 |
IP20 |
| Operation |
5 to 95%, non-condensing |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Material |
Robust metal housing |
| Width |
67.5 mm |
| Height |
257 mm |
| Depth |
219 mm |
| Weight |
3.75 kg |

Reviews
Clear filtersThere are no reviews yet.