Fast delivery within 72 Hours
B&R 1TGMPSAFETYX.00-01
User interface for VC4-based HMI applicationsFor up to 8 SafeBOOL or 8 SafeINT parametersFor single-choice or multiple-choice applications
Component mapp S…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
User interface for VC4-based HMI applicationsFor up to 8 SafeBOOL or 8 SafeINT parametersFor single-choice or multiple-choice applications
Component mapp SafeOPTION or MpSafetyX provides secure data exchange between HMI elements and the SafeLOGIC controller. This makes it possible to transfer safety-related parameters from the HMI application to the safety application. Typical use cases include selecting an operating mode or defining limit or threshold values.One “OptionManager” function block is supported per SafeLOGIC controller during configuration in Automation Studio. Up to 16 option function blocks can then be used per “OptionManager” function block. The following option function blocks are available:MpSafetyXOptionIntUI: This function block can be used to configure up to 8 SafeBOOL parameters. Either “Multiple-choice” or “Single-choice” mode is possible.MpSafetyXOptionBoolUI: This function block can be used to configure up to 8 SafeINT parameters.Suitable function blocks for configuration in SafeDESIGNER are included in library “SafeOPTION_SF”.
Specification
| Mapp Technology |
1TGMPSAFETYX.00-01 B&R software license |
|---|---|
| Automation Studio |
4.2.5 or later |
| Automation Runtime |
F4.25 or later |
| SafeDESIGNER |
4.2.3 or later |
| Safety Release |
1.10 or later |
| Single-user license |
Runtime license |
| Alternative package license |
mapp flat-rate 1TGMPFLAT.02 |
| Behavior if license missing |
Solid red LED indicates license violation |
| Diagnostics |
Via Automation Studio (SDM, Logger, etc.) |
| CRA (Cyber Resilience Act) |
Not applicable |
| Functional safety |
IEC 61508:2010, SIL 3 |
| Included library |
MpSafetyX |
| Tracing variable values |
No |
| Dynamic variable assignment |
No |
| Recordings |
No |
| Data archival |
None |
| Data exchange |
Secure data exchange between HMI elements and the SafeLOGIC controller over 2 communication channels. |
| Modular software concepts |
Supported |
| Web-based diagnostics |
Yes |
| XML configuration |
Yes |
| Use cases |
– Safe mode selector switch |