Fast delivery within 72 Hours

Wago 767-3801

Short description:This digital input module records binary signals from switches, sensors and proximity sensors (BEROs).Features:8 digital inputs, 24 VDCDiagnostic-capable (module by module)Parameteri…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Short description:This digital input module records binary signals from switches, sensors and proximity sensors (BEROs).Features:8 digital inputs, 24 VDCDiagnostic-capable (module by module)Parameterizable (filter, inversion, online simulation and diagnostics)Includes:1 x module marker (WMB), yellow1 x marking strip2 x M8 protective cap

Specification

Technical data

Number of digital inputs8
Total number of channels (module)8
Signal typeVoltage
Signal type (voltage)24 VDC
Sensor connection8 x (2-wire, 3-wire)
Input characteristichigh-side switching
Input characteristicType 2, per IEC 61131-2
Input filter0.1, 0.5, 3, 15, 20 ms
Input filterHardware: ≤ 80 µs; Software: parameterizable
Input current per channel for signal (0) max.2.4 mA
Input current per channel for signal (1) typ.7.3 mA
Input current per channel for signal (1) min.6.4 mA
Input current per channel for signal (1) max.7.4 mA
Voltage range for signal (0)−3 … +5 VDC
Voltage range for signal (1)11 … 30 VDC
Process data width1-byte data + status
Parameterizable functionsI/O diagnostics (per module): Short circuit/overload (sensor supply); Undervoltage (ULS + UA), Online simulation (per module): Diagnostics, Online simulation (per channel): Lock/Unlock; Simulation value: 0/1, Input filter (per channel): 0.1/ 0.5/ 3 /15 /20 ms/ Filter "Off", Inversion (per channel): On/Off
ProtectionReverse voltage protection for ULS + UA; Short circuit protection for sensor supply
Supply voltage (system and sensor)24 VDC(-25 … +30 %); Logic and sensors (ULS)
Current consumption: System and sensor40 mA
System and sensor power consumption (note)+ sensors (max. 400 mA)
Supply voltage (field)24 VDC (-25 … +30 %); Actuators (UA), for transmission only
Current consumption, field supply (module with no external load)5 mA
Isolation500 V supply/system bus
IndicatorsLED (F) red: Error status; LED (SB) green/red/orange: System bus status; LED (ULS, UA) green: Power supply status; LED (0 … 7) yellow: Status/diagnostics DI 1 … DI 8; Non-retentive displays
Current carrying capacity (supply connections)8 A
Connection of 2-wire BEROsAdmissible closed current: 1.5 mA (max.)

Connection data

Connection technology: I/O8 x M8 socket; 3-pole
Connection technology: field supply1 x M12 plug; 4-pole; A-coded; 1 x M12 socket; 4-pole; A-coded
Connection technology: system supply1 x M12 socket; 4-pole; A-coded; 1 x M12 plug; 4-pole; A-coded
Connection technology: system bus1 x M12 socket, 5-pole, B-coded, shielded; 1 x M12 plug, 5-pole, B-coded, shielded
Connection requirement (permissible cable length)30 m
Connection requirement (permissible cable type)Digital inputs: unshielded

Physical data

Width50 mm / 1.969 inches
Height35.7 mm / 1.406 inches
Depth117 mm / 4.606 inches

Material data

Colorlight gray
Housing materialPolyamide (PA), Makrolon (address switch cover), flammability per UL94-V0, halogen/silicon-free
Fire load0.015 MJ
Weight242 g
Conformity markingCE
EncapsulationPolyurethane (PUR), halogen/silicon-free

Environmental requirements

Ambient temperature (operation)-25 … +60 °C
Ambient temperature (storage)-40 … +85 °C
Protection typeIP67
Protection classIII
Operating altitude−1000 … 2000 m; Air pressure: 1080 … 795 hPa
Relative humidity (without condensation)95 %
Vibration resistance5g per IEC 60068-2-6
Shock resistanceShort-term: 50g/11 ms/half-sine per IEC 60068-2-27; Long-term: 30g/6 ms/half-sine per IEC 60068-2-29
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-4
Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %0.1 ppm
Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %0.5 ppm

Commercial data

Product Group15 (I/O System)
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
GTIN4045454545185
Customs tariff number85389099990
End of Sale2018-09-30
End of Production2018-10-05
End of Delivery2018-10-15
End of Service and Repair2020-09-29

Product Classification

UNSPSC32151705
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 79-94-7
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)c4af479c-f223-4e75-b1e7-915a406b72dd
SCIP notification number (Belgium)0a085c1c-53da-4eda-922d-ec03b42e2fd5
SCIP notification number (Bulgaria)56fc8e0a-7f58-4cd2-ae76-580bde444b0f
SCIP notification number (Czech Republic)e7218df5-32d8-4ade-9882-7857ae125601
SCIP notification number (Denmark)60d77a4c-686a-468e-963b-1b40bbc6f9db
SCIP notification number (Finland)f302004f-6c28-4ade-ab9b-1d950d49fb29
SCIP notification number (France)a6ce0b38-25de-40b6-80f0-ee9c3d91f9c4
SCIP notification number (Germany)b6e776bd-ac84-40e6-beb8-0acd8bd89485
SCIP notification number (Hungary)67393907-446c-4db3-95ec-858f22c3025c
SCIP notification number (Italy)ca38b2da-3685-4193-a376-63537fb5b410
SCIP notification number (Netherlands)30eb7a62-9bc5-4467-a486-3119e7c7f996
SCIP notification number (Poland)5d94ee54-8bdd-42c7-bffe-645f56dc8503
SCIP notification number (Romania)fa176782-b3bb-40bf-9024-e8f95a2e309d
SCIP notification number (Sweden)e5cce26e-fcf0-46cf-a739-aec7a0ef275e

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.